Generator Quick Start Guide

• 4 • Model 802 Series Quick Start Guide
Notes:
If the format and image names are shifted to
the left side of the LCD the unit is running in
a user defined Test Sequence mode from the
front panel. Information on creating a Test
Sequence using VGM software is on page
16.
Front Panel Controls and Indicators (Normal Mode)
If there is a combination of two letters and a
number to left of the equal sign in the top row
of the LCD, the unit is in Detailed Status
display mode. Information on setting this
mode and the meaning of the letters and
numbers can be found on page 10.
802
Video
Test
Generator
Image Video Gate
STEP R G B ACS DCS DSS ON
Image
Format
Outputs
Power On Indicator
Current
Test Image
Horizontal Rate
nearest KHz
Current
Format
Vertical Rate
nearest Hz
LCD Window Information
Sync Gate
Image/ Step
Button
Draws alternate
versions of test
images
Video Gate
Buttons
Turn individual
video elements
on or off
Sync Gate
Buttons
Turn different
sync types on
and off
Outputs
Button
Turns all
signal outputs
on and off
Format Knob
Selects a video
signal format from
knob list
Image Knob
Selects a test
image (pattern)
from knob list
H31 219=VGA_3
V60 198=SMPTE133
DMT0660 NewSeq
Outline0 S1
H31 D4C=DMT0660
V60 1=Outline0