Owner's manual
881/882 Video Test Generator User Guide (Rev A.22) AOW
2080 Pixel rate too low
The video format’s total (active + blanked) number of pixel clock cycles per horizontal scan
line multiplied by the horizontal scan rate is less than the minimum pixel clock frequency
supported by the generator hardware configuration for the format video type.
2082 Number of bits not allowed
The generator hardware configuration does not support the number of data bits per color
for the serial digital video type selected in the video format.
2083 Invalid quantizing mode
An invalid value has been specified for the digital video quantizing mode (DVQM)
parameter.
2084 Invalid Pixel Repetition
In digital mode, double clocking is not supported for this specific hardware. This error may
be the result of an older FPGA or hardware.
2085 Invalid Sampling Mode
The value specified for digital video sampling mode (DVSM) is not valid and is inconsistent
with the setting of digital video signal type (DVST).
2086 Invalid Video ID Code
The value specified for the CEA-861 Video Identification Code (VIC) with the DVIC
parameter is invalid.
2087 Invalid Number of Bits per Audio Sample
The value specified for number of bits per audio sample (NBPA) is invalid.
2088 Invalid Sampling Rate
The value specified for audio sampling rate (ARAT) is invalid.
2089 Invalid Number of Audio Streams
The value specified for number of audio streams (NDAS) is invalid.
2090 Horizontal total not even
The generator hardware configuration does not support interlaced video formats with a
total (active + blanked) number of pixel clock cycles per horizontal scan line that is not
evenly divisible by 2.
-OR-