2230 Horizontal pulse delay extends sync beyond blanking
The generator hardware configuration does not support the video format’s combination of
horizontal sync pulse delay and pulse width that places any portion of the horizontal sync
pulse outside of the horizontal blanking period.
2231 Vertical serration adjustment too big
The video format’s HVSA setting beyond the maximum limit for the video type selected
and generator hardware configuration.
2240 Vertical total too small
The total (active + Blanked) number of horizontal scan lines per frame a progressive scan
(non-interlaced) video format is lees than the minimum supported by the generator
hardware configuration.
2250 Vertical total too small for interlaced format
The total (active + blanked) number of horizontal scan lines per frame is less than the
minimum number supported by the generator hardware configuration.
2270 Vertical total is even
The generator hardware configuration does not support interlaced scan video formats
having an even total (active + blanked) number of horizontal scan lines per frame.
2280 Vertical total too large
The total (active + blanked) number of horizontal scan lines per frame exceeds the
maximum limit for the generator hardware configuration.
2300 Vertical active too small
The active number of horizontal scan lines per frame of a progressive scan
(non-interlaced) video format is less than the minimum supported by the generator
hardware configuration.
2310 Vertical blanking too small
The number of blanked horizontal scan lines per frame for a progressive scan
(non-interlaced) video format is less than the minimum supported by the generator
hardware configuration.
2320 Vertical active too small for interlaced format
The active number of horizontal scan lines per frame of an interlaced video format is less
than the minimum supported by the generator hardware configuration.