Owner's manual
881/882 Video Test Generator User Guide (Rev A.22) APC
2321 Vertical active not even
The generator hardware configuration does not support interlaced scan video formats
having an odd active number of horizontal scan lines per frame.
2330 Vertical blanking too small for interlaced format
The number of blanked horizontal scan lines per frame for an -interlaced video format is
less than the minimum supported by the generator hardware configuration.
2350 Vertical pulse too small
The vertical sync pulse width is less than the minimum supported by the generator
hardware configuration.
2370 Vertical pulse too large
The vertical sync pulse width is greater than the maximum supported by the generator
hardware configuration.
2390 Vertical pulse too large for interlaced format
The vertical sync pulse width combined with the number of pre and post-equalization
pulses for an interlaced format is greater than the maximum supported by the generator
hardware configuration.
2391 Incompatible analog composite sync & digital composite sync types
The generator hardware configuration does not support the video format outputting both
analog composite sync and digital composite sync type selections at the same time.
2392 Incompatible analog composite sync & digital separate sync types
The generator hardware configuration does not support the video format outputting both
analog composite sync and digital separate sync type selections at the same time.
2393 Analog composite sync type not compatible with analog video type
The generator hardware configuration does not support the video format’s analog
composite sync type being added to the current analog video type.
2394 ACS available on green only
The generator hardware configuration supports adding analog composite sync to only the
green analog video output
2395 Sync type selection incompatible with analog video type selection
The video format’s analog video type selection requires the use of analog composite sync.