Owner's manual
514 Chapter 16 Testing EDID
3. Read the EDID from the display as follows:
a. Press the Sink key. The following information appears on the generator’s display.
b. Press the Options key. The following information appears on the generator’s
display.
c. Choose the EDID Formats item by pressing the adjacent soft key. A + appears next
to EDID Formats, indicating it is enabled.
The generator loads the Source list with formats supported by the connected display
(hot-plug formats read via EDID structure of attached display).
Note: To disable hot plug formats, press the soft key adjacent to EDID Formats. A -
next to EDID Formats indicates it is disabled.
4. Press the Content key. A list of images appears on the generator’s display.
5. Choose the EdidData image by pressing the adjacent soft key. The image appears on
the display as shown below.
Alternatively, to select the image using the command line interface, enter the following
commands:
IMGL EDIDDATA // Loads the EdidData image
Manufacturer:SNY
Product Code:144
Serial#:7011007
Week:20 Year:1998
-EDID Formats CDF
+HP Bypass
-Emulate