Owner's manual

660 Chapter 18 Testing HDCP
5. Select EditPCP to define the capabilities of the HDCP device under.
Note: For the sink device tests there are no parameter settings required. You will only
need to set the device type to sink.
The following table describes the test parameters and their settings.
6. Select Sink device by pressing the adjacent soft key to specify that the device under
test is a sink.
The following is displayed on the generator’s LCD.
Alternatively, you can specify the device under test as a sink using the following
commands:
CPTX:DUTT 0 // specifies device under test as a sink (receiver)
7. Specify the remaining parameters in the EditPCP menu using the table above.
8. Press the Enter/Options key to save the capabilities definition.
The generator LCD will display the message “Saved”.
9. Press the Tools key get back to the Reports menu.
The generator LCD will display the reports menu as shown below.
10. Select HDCP to access the HDCP compliance test menu.
The following is displayed on the generator’s LCD.
Parameter Explanation
Device Under Test type The type of device under test. For this test, select Sink
(Receiver).
Source :DUT Type
+Src_Fld_CPIRQ_R0’
+Src_Fld_CPIRQ_RDY
+Source_Out_OnlyRep
Sink :DUT Type
+Src_Fld_CPIRQ_R0’
+Src_Fld_CPIRQ_RDY
+Source_Out_OnlyRep
EDID
Misc HDCP
!CompRpt EditPCP