Quick Start Guide

21 882E Quick Start Guide - HDCP Compliance Testing with Encryption Status Tester (EST) - P/N 68-00210 Rev. B
7. Select HDCP to access the HDCP compliance test menu.
The following is displayed on the generator’s LCD.
8. Select EditPCP to define the capabilities of the HDCP device under.
The following is displayed on the generator’s LCD.
The following table describes the test parameters and their settings (gray = N/A).
Parameter Explanation
DUT type The type of device under test. This can be one of Sink,
Source, Repeater, Repeater3AB, or Repeater3C. For
this test, select Repeater3AB.
Source Max KSV Specifies the maximum number of KSVs the source can
read. The valid values are 1 through 127.
Source Authentication Control Specifies the number of times a source DUT attempts
authentication before transitioning into the authentica-
tion state. The valid values are 1 or greater.
Source Out Only Repeater Indicates whether the DUT outputs contents to a
repeater to which no downstream device is connected.
The values are + for yes and - for no.
Sink 1.1 Features Supported Indicates whether the DUT supports Advanced_Cipher
mode and Enhanced Link Verification. The values are +
for yes and - for no.
Sink 1.1 Audio Supported Indicates whether the DUT supports audio output. The
values are + for yes and - for no.
Repeater 1.1 Features Supported Indicates whether supports Advanced_Cipher mode
and Enhanced Link Verification. The values are + for yes
and - for no.
Repeater Audio Support Indicates whether the DUT supports audio output. The
values are + for yes and - for no.
Repeater HPD Pulse Indicates whether the DUT has the capability to output
HPD pulse by user operation. The values are + for yes,
repeater DUT allows the user to initiate a HPD; and - for
no, the repeater DUT does not support a user to manu-
ally force of a hot plug pulse.
!CompRpt EditPCP
Source :DUT Type
0
1
+Source_Out_OnlyRep
:Source_Authe_Cnt
:Source_Max_KSV