Automation and Control IP 67 I/O Splitter Boxes Catalog January 07 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.
Telefast®, Telemecanique®, Zelio®, Twido®, Modicon®, Phaseo®, TeSys®, Altivar®, Premium™, Advantys™, and Quantum™ are trademarks or registered trademarks of Schneider Electric. Other trademarks used herein are the property of their respective owners. Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.
Contents 0 IP 67 I/O Splitter Boxes IP 67 passive splitter boxes Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 4, 5 b Telefast® Distribution Systems, ABE9 splitter boxes. . . . . . . . . . . . . . . . page 6, 7 v Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8 v References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IP 67 I/O Splitter Boxes and Modules Passive splitter boxes Monobloc I/O splitter boxes and modules Telefast® ABE9 splitter boxes Advantys™ FTB splitter boxes 108737 Splitter box and module type 0 521940 0 108733 Selection guide Fieldbus type – CANopen™ DeviceNet™ Profibus™-DP InterBus™ Number of inputs/outputs 8 I/O, 16 I/O 16 I, 8 I + 8 O, 12 I + 4 O, 16 I/O, 8 I + 8 I/O Type of signal Digital Functions Connection of 1 to 16 sensors/actuators Type of input/output connectors M12 (M8
0 0 Modular I/O splitter boxes 108741 108743 540351 Advantys, FTM splitter boxes CANopen™ DeviceNet™ Profibus™-DP 8 I, 16 I, 8 I/O and 16 I/O, digital 4 I or 4 O, analog Digital and analog Connection of 1 to 256 sensor/actuators per bus module M8 and M12 Plastic only FTM 1 48 5 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.
Presentation 0 IP 67 passive splitter boxes 0 Telefast® Distribution System, ABE9 splitter boxes Presentation ABE9 passive splitter boxes for M12 connectors make it possible to eliminate long and difficult cabling operations. Due to their modularity and their dimensions, they are the ideal solution for a wide variety of customer applications. Connection to the processing unit can either be made by connector or by multicore cable of different lengths.
Description 0 IP 67 passive splitter boxes 0 Telefast® Distribution System, ABE9 splitter boxes Description Passive splitter boxes ABE 9C12ppC23 have the following on the front face: 1 1 Four or eight M12 female connectors (depending on model) for connection of sensors and actuators (2 channels per connector). 2 2 Eight or sixteen channel status indicator lights (depending on model). 3 One “Power on” indicator light on the splitter box (depending on model). 4 One M23, 19-pin male connector.
Characteristics, substitution IP 67 passive splitter boxes 0 0 Telefast® Distribution System, ABE9 splitter boxes Splitter box type ABE 9C12p0C23 ABE 9C12p1C23 ABE 9C12p0Lpp, ABE 9C12p0M ABE 9C12p1Lpp, ABE 9C12p1M Environmental characteristics Product certifications Temperature cULus Operation Storage °C (°F) °C (°F) - 20 to + 80 (- 4 to + 176) - 40 to + 85 (- 40 to + 185) IP 67 Hz 10 ≤ f ≤ 57 (constant amplitude = 1.5 mm) 57 ≤ f ≤ 150 (constant acceleration = 0.
References 0 IP 67 passive splitter boxes Telefast® Distribution 0 System, ABE9 splitter boxes References 562511 562421 Splitter boxes with connection by M23 connector Number of channels 4 Connection by 4 x M12 female connectors LED indicator With Without Reference Weight kg ABE 9C1241C23 0.080 ABE 9C1240C23 0.080 8 8 x M12 female connectors With Without ABE 9C1281C23 ABE 9C1280C23 LED indicator With Without Reference Weight kg ABE 9C1241L05 0.680 ABE 9C1240L05 0.
IP 67 passive splitter boxes Dimensions, connections 0 0 Telefast® Distribution System, ABE9 splitter boxes Dimensions ABE 9C124pLpp 50.2 1.97" 36.5 1.44" 26.5 1.04" ABE 9C128pC23 15.5 (0.61") 33 1.29" 39 1.53" 42 1.65" ABE 9C128pLpp 50.2 1.97" 50.2 1.97" 2xØ4.5 (0.80") 4.5 0.17" 4.5 0.17" 33 1.29" 39 4.5 0.17" 15.5 (0.61") 4.5 0.17" 73 2.87" 73 2.87" 149.2 5.87" 149.2 5.87" 34 1.33" 34 1.33" 2xØ4.5 20.4 Ø4.5 73 2.87" 92.2 3.62" 4.5 0.17" 33 1.29" 39 1.53" 4.5 0.17" 4.
Connections (continued) IP 67 passive splitter boxes 0 0 Telefast® Distribution System, ABE9 splitter boxes 1…4/5 1…4/1 – + 4/2 4/4 3/2 3/4 2/2 2/4 1/2 1/4 1…4/3 ABE 9C124pC23 3 1 5 4 4 4 3 5 2 1 5 2 2 1 4 3 1 3 1 2 5 3 2 4 Item 1/4 1/2 2/4 2/2 3/4 3/2 4/4 4/2 1 and 3/1 2 and 4/1 1 and 3/3 2 and 4/3 1 to 4/5 Contact 15 7 5 12 11 1 4 10 18 17 13 16 19 9 8 16 14 3 8 15 14 7 5 6 19 19 6 M23 connector 6 12 Item 1/4 1/2 2/4 2/2 3/4 3/2 4/4 4/2 5/4 5/2 6/4 6/2 7/4 7/2 8/4
Selection guide 0 IP 67 monobloc I/O splitter boxes for fieldbuses Advantys™ Distributed 0 I/O, FTB splitter boxes Applications Industrial fieldbus type Degree of protection IP 67 Modularity (number of channels) 8 I + 8 O (8 O + 8 diagnostic inputs) p – 12 I + 4 O (4 I + 4 O + 8 diagnostic inputs) p – 16 I (8 I + 8 diagnostic inputs) p p 16 I/O (8 I/O+ 8 diagnostic I/O) p p 8 I + 8 I/O (8 I + 8 diagnostic I/O) – p Voltage c 24 V Conformity to IEC 1131-2 Type 2 Voltage c 24 V Ty
0 0 INTERBUS IP 67 IP 67 IP 67 p – p – p p – p – p p p p p p p p p p p – p – p – c 24 V c 24 V c 24 V Type 2 Type 2 Type 2 c 24 V c 24 V c 24 V Transistor Transistor Transistor 1.6 A 1.6 A 1.
Presentation, functions 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes Presentation To meet the needs of machine manufacturers and users, automation system architectures are becoming decentralized, while offering performances comparable to those obtained with a centralized structure.
Functions (continued) 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes Diagnostics Each Advantys FTB splitter box has one LED per channel to indicate the status of the channel and to enable fast and precise location of a fault. Fault monitoring diagnostics are indicated on the splitter box by LEDs and are fed back to the control system (PLC) via the bus. There are 2 levels of diagnostics: b diagnostics per channel, b diagnostics per splitter box.
Presentation 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes CANopen™ and DeviceNet™ bus extensions Advantys FTB splitter boxes are of the monobloc type. Each splitter box comprises one part for connection of sensors and actuators by means of M12 connectors, and one part for connection of splitter boxes on CANopen and DeviceNet fieldbuses.
Presentation (continued) 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes CANopen™ and DeviceNet™ bus extensions DeviceNet bus presentation DeviceNet Master DeviceNet bus From 1 to 63 Slaves Modicon® Momentum™ PLC Altivar® 38 Drive ® Altivar® 58/58F Drive TeSys Model U FTB 1DN FTB 1DN Tego® Power Connections The DeviceNet system is a sensor/actuator bus system of the open Low-End type, used in various industrial applications and, in particular, the
Description, configuration 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes CANopen™ and DeviceNet™ bus extensions Description 540354 CANopen and DeviceNet monobloc I/O splitter boxes FTB 1CN and FTB 1DN have the following on the front face: 1 2 3 9 7 8 4 1 Eight M12 female connectors for connection of sensors and actuators (2 channels per connector). 2 Eight channel status indicator lights (00 to 07).
Connections 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes CANopen™ and DeviceNet™ bus extensions Cabling system Master To other splitter box 7 c 24 V 8 3 9 5 4 ATV 58 FTB 1CN/1DN FTB 1CN/1DN 7 6 2 1 Cabling accessories CANopen and DeviceNet bus connection cables Cables FTX CN32pp enable connection of splitter boxes FTB 1CN and FTB 1DN to CANopen and DeviceNet fieldbuses.
Presentation 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes Profibus™-DP bus Advantys FTB splitter boxes are of the monobloc type. Each splitter box comprises one part for connection of sensors and actuators by means of M12 connectors, and one part for connection of splitter boxes on Profibus-DP fieldbus. This splitter box enables inputs/outputs to be located remotely, as close as possible to the equipment being controlled.
Description, configuration 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 108734 Advantys™ Distributed I/O, FTB splitter boxes Profibus™-DP bus Description 1 2 3 Profibus-DP monobloc I/O splitter boxes FTB 1DP have the following on the front face: 1 Eight M12 female connectors for connection of sensors and actuators (2 channels per connector). 2 Eight channel status indicator lights (00 to 07).
Connections 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes Profibus™-DP bus Cabling system Modicon® Quantum™ PLC Other Master Modicon® Premium™ PLC 9 10 5 11 7 6 FTB 1DP FTB 1DP 4 3 1 9 9 Altivar® 58 Drive FTB 1DP 8 2 Cabling accessories Profibus-DP bus connection cables Cables FTX DPp2pp enable connection of splitter boxes FTB 1DP to Profibus-DP fieldbus.
Presentation 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes InterBus™ bus extenson Advantys FTB splitter boxes are of the monobloc type. Each splitter box comprises one part for connection of sensors and actuators by means of M12 connectors, and one part for connection of splitter boxes on InterBus fieldbus. This splitter box enables inputs/outputs to be located remotely, as close as possible to the equipment being controlled.
Description, configuration 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes InterBus™ bus extention 108730 Description 1 2 3 InterBus monobloc I/O splitter boxes FTB 1IB have the following on the front face: 1 Eight M12 female connectors for connection of sensors and actuators (2 channels per connector). 2 Eight channel status indicator lights (00 to 07).
Connections 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes InterBus™ bus extension Cabling system Other Master Modicon® Quantum™ PLC Modicon® Premium™ PLC 2 3 Modicon® Momentum™ PLC 4 FTB 1IB FTB 1IB 1 Cabling accessories Connection cables for the bus and for sensor and actuator c 24 V power supplies Cables FTX IB12pp enable connection of splitter boxes FTB 1IB to InterBus fieldbus.
Characteristics 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes Environmental characteristics Product certifications cULus Temperature Operation Storage Degree of protection Conforming to IEC 60529 Altitude Vibration resistance Shock resistance Conforming to IEC 68-2-6, test Fc °C (°F) 0 to + 55 (+ 32... 131) °C (°F) - 25 to + 70 (-13...+ 158) IP 67 m (ft.) 0 to 2000 (0 to 6562) Hz For plastic housing 5 ≤ f ≤ 57.55 (constant amplitude = 1.
Characteristics (continued) 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes Input/output characteristics Splitter box type Bus type FTB Number of inputs/outputs 1pp16Epp 1pp08E08SPp All types of bus 1pp12E04SPp 1pp16Cpp 16 I (8 I + 8 diagnostic inputs) 16 I/O (4 I + 4 O + 8 diagnostic inputs) 16 I/O (8 I/O + 8 diagnostic I/O) 8I 12 I 0...16 I – – 8O Transistor 4O 0...
References 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes 521940 108733 Number of I/O FTB 1CNpppP0 Number, type of inputs (1) Number, type of outputs (2) Connection by Housing Reference type Weight kg Monobloc splitter boxes for CANopen bus 16 FTB 1CNpppM0 8 8, transistor 8 x M12 female Plastic connectors FTB 1CN08E08SP0 0.430 12 4, transistor 8 x M12 female Plastic connectors FTB 1CN12E04SP0 0.
References (continued) 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes Connection accessories Description Composition Length m (ft.) Reference Weight kg 108767 For CANopen/DeviceNet buses Bus connection cables c 24 V power supply connection cables Connectors FTX DP2115 Line terminator (for end of bus) T-connector for power supply Fitted with 2 elbowed 0.3 (0.98) FTX CN3203 M12, 5-pin connectors, 0.6 (1.
References (continued) 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes Separate components Description Composition Reference Weight kg 7/8 male, 5-pin 7/8 female, 5-pin For M8 connector (lot of 10) For M12 connector (lot of 10) For 7/8 connector FTX C78M5 FTX C78F5 FTX CM08B FTX CM12B FTX C78B 0.050 0.050 0.100 0.100 0.
Dimensions 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes 50.5 (1.98") 63 (2.48") (1) (1) Ø 4 elongated hole 220 (8.66") 208 (8.18") FTB 1IBpppP1 208 (8.18") 220 (8.66") FTB 1CNpppP0, FTB 1DNpppP0, FTB 1DPpppP0 69 (2.71") 63 (2.48") (1) (1) Ø 4 elongated hole 224.7 (8.84") 208.5 (8.20") FTB 1CNppppppM0, FTB 1DNppppppM0, FTB 1DPppppppM0 20.5 (0.80") 62.7 (2.46") (1) 38.9 (1.53") (1) Ø 6 elongated hole 45 (1.77") FTX CY1212 45 (1.
Connections 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes Sensor/actuator connection Y-connector connection FTX CY1208 FTX CY1212 M8 female M8 female 1 24 V 2 S1 1 3 4 S2 5 0V 4 M12 female connector Supply input Bus input/Bus output Supply output Bus input Bus output CAN-L 3 4 2 0V 0V 0V 0V 24 V (1) 2 1 5 CAN-L 3 24 V (1) 24 V (2) 1 2 3 4 5 1 2 3 4 5 M12 male 1 2 3 4 M12 male CANopen and DeviceNet buses Supply to sp
Connections (continued) 0 IP 67 monobloc I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTB splitter boxes InterBus bus Connections to splitter box Supply to splitter box 1 Supply input 2 Supply output + 24 V/L + 24 V/R + 24 V/IN + 24 V/L + 24 V/R + 24 V/IN 0/ 24 V 0/ 24 V 1 3 2 4 0/ 24 V 0/ 24 V Bus input/Bus output 3 Local bus, bus input / DO1 DO1 / DI1 DI1 COM Green 3 Main bus, bus input Green/Yellow PE Blue 0V Red + 24 V Shielding SHD Yellow Pink Grey Brown 4 Local
Selection guide IP 67 modulor I/O splitter boxes for fieldbuses 0 0 Advantys™ Distributed I/O, FTM splitter boxes Degree of protection IP 67 Bus connector type M12, A encoded Maximum number of digital I/O per bus module 256 Maximum number of splitter boxes per bus module 16 Maximum number of splitter boxes per segment 4 540351 540351 540351 Bus modules FTM Industrial fieldbus type M12, A encoded M12, B encoded FTM 1CN10 FTM 1DN10 FTM 1DP10 48 48 48 Bus module type Pages 34 Court
0 Digital inputs/outputs Analog inputs/outputs 109017 108741 Splitter boxes FTM (not governed by the type of fieldbus) 108745 Selection guide Degree of protection IP 67 Bus connection Internal bus + 24 V power supply by M12, 6-pin connectors Splitter box type Compact Connector type M8 Modularity Number of channels 8I 8 I/O Digital inputs Digital outputs Analog inputs/outputs Diagnostics Expandable Compact M12 M8 M12 M12 8I 8 I/O 16 I 16 I/O 8I 8 I/O 8I 8 I/O 16 I 16 I/O 4I 4O
Presentation 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes Presentation To meet the needs of machine manufacturers and users, automation system architectures are becoming decentralized, while offering performances comparable to those obtained with a centralized structure.
Presentation (continued) 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes 5 m (16.4 ft.) max. (1) Segment 2 Segment 1 Segment 3 4 splitter boxes max. Presentation (continued) The topology of the system is a star/line architecture. Each bus module is fitted with four M12 connectors for the connection of Advantys FTM splitter boxes (star architecture).
Functions 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes Functions Selection of signal type per channel b Each M12, 5-pin connector on Advantys FTM splitter boxes allows the connection of 2 signals. Depending on the type of splitter box, these can be: v 1 sensor input signal, v 1 diagnostic input signal, v 1 actuator output signal.
Functions (continued) 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes Functions (continued) Diagnostics per splitter box b Sensor/actuator supply status. b “Undervoltage” fault on the I/O supply. b Sensor short-circuit. b Actuator short-circuit.
Presentation (continued), configuration 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes CANopen bus presentation Other Master Modicon® Premium™ PLC CANopen bus ® 58 Drive From 1 to 127 Slaves FTM 1CN FTM 1CN Altivar TeSys® Model U ® Tego Power Connection The CAN system, initially developed for real-time exchange of information in the automobile industry, is now being used more and more throughout industry.
Presentation (continued), configuration 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes DeviceNet bus presentation Other Master Modicon® Premium™ PLC From 1 to 63 Slaves DeviceNet bus Modicon® Momentum™ PLC ® 58 Drive Altivar TeSys® Model U FTM 1DN FTM 1DN ® Tego Power Connection The DeviceNet system is a sensor/actuator bus system of the open Low-End type, used in various industrial applications and, in particular, the automobile industry.
Presentation 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes Profibus-DP presentation Modicon® Quantum™ PLC Other Master Profibus-DP bus Modicon® Premium™ PLC ® 58 Altivar Drive Modicon® Momentum™ PLC FTM 1DP FTM 1DP FTM 1DP FTM 1DP The Profibus-DP (Process Fieldbus Decentralized Peripheral) is an open type fieldbus system for industrial applications. The Profibus standard is described in standard EN 50170.
Description 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes 1 12 2 Description 7 6 3 8 9 4 Modular bus modules FTM have the following on the front face: 1 One M12 male connector (bus IN) for connection of the bus. 2 One M12 female connector (bus OUT) for connection of the bus. 3 One 7/8 male connector for connection of the c 24 V power supplies. 4 Four M12 female connectors for connection of the splitter box inputs/outputs via the internal bus.
Connections IP 67 modular I/O splitter boxes for fieldbuses 0 0 Advantys™ Distributed I/O, FTM splitter boxes 8 CANopen and DeviceNet bus 6 1 9 10 c 24 V FTM 1CN/1DN 5 FTM 1CN/1DN 4 8 7 9 2-3 Profibus-DP bus 10 c 24 V FTM 1DP 5 FTM 1DP 4 15 11 11 12 + 24 V 11 FTM 1DD16C12 FTM 1Dp08C08 14 13 FTM 1DE16C12 FTM 1Dp08C12E 15 FTM 1Dp08C08E 16 14 FTM 1Dp08C12 FTM 1Ap04C12p FTM 1Dp16C12E Note: the I/O splitter boxes are not governed by the type of fieldbus.
Connections (continued) 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes Cabling accessories for bus modules Bus module to bus connection cables Various cables enable connection of the bus module to the fieldbus. They are available in different lengths: CANopen and DeviceNet buses: 1 FTX CN32pp: cables fitted with 2 elbowed M12, 5-pin connectors, one at each end, for connecting the bus between two bus modules.
Characteristics 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes Environmental characteristics Product certifications Temperature Degree of protection Altitude Vibration resistance Shock resistance Resistance to electrostatic discharge Resistance to radiated fields Immunity to fast transient currents Surge withstand Immunity to conducted disturbance Resistance to magnetic fields, 50 Hz Mounting Mechanical mounting Operation Storage Conforming to IEC 6
Characteristics (continued) 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes Digital input/output splitter box characteristics Splitter box type Number of inputs/outputs Internal consumption of splitter box mA Operating voltage Splitter box max. supply current Auxiliary supply max.
References 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes Bus modules for modular splitter boxes 108739 Bus type CANopen Maximum number of splitter boxes 16 Connection to bus by M12 connectors Reference FTM 1CN10 Weight kg 0.420 DeviceNet 16 M12 connectors FTM 1DN10 0.420 Profibus-DP 16 M12 connectors FTM 1DP10 0.
References (continued) 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes Connection accessories (continued) Description Composition Length m (ft.) Reference Weight kg – FTX DP12M5 0.050 – FTX DP12F5 0.050 – FTX DPTL12 0.010 FTX DP2206 FTX DP2210 FTX DP2220 FTX DP2250 FTX DP2115 FTX DP2130 FTX DP2150 FTX CNCT1 0.150 0.190 0.310 0.750 0.240 0.430 0.700 0.
Dimensions 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes Bus modules FTM 1pp10 125.3 (4.9") 20.5 (0.80") 151 (5.9") 5 34.5 (1.35") 22 50 (1.96") (0.86") 50.3 (1.98") 22 (0.86") 30 2 (0.078 ") 5 (0.19") 75 (2.9") 126 (4.96") (1.18") 34.5 (1.35") 4 75 (2.9") 4 151 (5.9") 5 (0.19") 34.5 (1.35") 75 (2.9") 75 (2.9") 4 30 FTM 1Dp08C08E 126 (4.96") 34.5 (1.35") FTM 1Dp08C12E 5 (0.19") FTM 1Dp08C08 4 50 (1.96") 50 (1.
Schemes 0 IP 67 modular I/O splitter boxes for fieldbuses 0 Advantys™ Distributed I/O, FTM splitter boxes Splitter box connection Input/output connection for digital splitter boxes Input/output connection for analog splitter boxes Analog input 1 24 V 2 S2 5 S1 3 0V 4 24 V + 24 V 0V 1 3 4 S Analog output 1 2 Analog 5 Analog input – signal 4 0V 3 5 Analog output signal 4 0V 3 M8 female connector Auxiliary power supply Bus input/Internal bus output of splitter boxes Internal bus
Selection guide 0 Power supplies 0 Power supplies for d.c. control circuits Functions Supplies for d.c. control circuits Type of product Single-phase, modular switch mode power supplies Single-phase, regulated switch mode power supplies Applications Industrial, commercial or residential applications. Modular format allowing integration into panels. Simple, low power equipment. Industrial applications, low and medium power. Machine equipment applications.
0 0 2-phase regulated switch mode power supplies 3-phase regulated switch mode power supplies Industrial applications. Industrial applications. In-line continuous process equipment, machine tools, injection presses, etc. 120 and 240 W 240 and 480 W 120 W a 2 x 380 to 415 V 2-phase a 3 x 380 to 415 V 3-phase 240 to 960 W a 3 x 400 to 520 V 3-phase c 24 V adjustable Primary switch mode electronic power supplies. Integrated, against overloads and short-circuits, with manual and automatic reset.
Presentation 0 Power supplies 0 Power supplies for d.c. control circuits Phaseo® modular regulated power supplies Modular switch mode power supplies ABL 7RM The ABL 7RM range of power supplies is designed to provide the d.c. voltage necessary for the control circuits of automation system equipment. Comprising 3 products, this range meets the needs encountered in industrial, commercial and residential applications.
Characteristics 0 Power supplies 0 Power supplies for d.c.
Characteristics (continued), selection Power supplies 0 0 Power supplies for d.c. control circuits Phaseo® modular regulated power supplies Output characteristics Exceeding the nominal power (only applicable to ABL 7RM1202 and ABL 7RM2401) The ambient temperature is a determining factor which limits the power that an electronic power supply can deliver continuously. If the temperature around the electronic components is too high, their life will be significantly reduced.
Power supplies References, dimensions, scheme 0 Power supplies for d.c. control circuits Phaseo® modular regulated power supplies 0 Modular regulated switch mode power supplies ABL 7RM (1) Mains input voltage 47 to 63 Hz V 100 to 240 Single-phase wide range Output voltage cV 12 Nominal power W 22 Nominal current A 1.9 Auto-protect reset Reference Weight Auto ABL 7RM1202 kg 0.180 24 30 60 1.3 2.5 Auto Auto ABL 7RM2401 ABL 7RM24025 0.182 0.
Presentation 0 Power supplies 0 Power supplies for d.c. control circuits Phaseo® regulated switch mode power supplies ABL 7 power supplies The ABL 7 range of power supplies is designed to provide the d.c. voltage necessary for the control circuits of automation system equipment. Split into three families, this range meets all the needs encountered in industrial, commercial and residential applications.
Presentation (continued) 0 Power supplies 0 Power supplies for d.c.
Selection 0 Power supplies 0 Power supplies for d.c. control circuits Phaseo® regulated switch mode power supplies Selection of power supplies The characteristics to be taken into account when selecting a power supply are: - the required output voltage and current, - the mains voltage available in the installation. An initial selection can be made using the table opposite. This may however result in several products being selected as suitable.
Selection (continued) 0 Power supplies 0 Power supplies for d.c. control circuits Phaseo® regulated switch mode power supplies Selection according to application characteristics Type of mains supply Rated mains supply voltage Permissible variation Output voltage Output current Single-phase a 100 to 240 V 50/60 Hz c 110 to 220 V (1) Wide range 85 to 264 V, 47 to 63 Hz c 100...250 V (1), c 105...370 V (2) 12 V 48 V 24 V 0.
Characteristics 0 Power supplies 0 Power supplies for d.c. control circuits Phaseo® regulated switch mode power supplies Technical characteristics Type of power supply Product certifications Conforming to standards Safety ABL 7CEM cULus, TÜV UL 508 IEC/EN 60950, FELV EN 50081-2, EN 50082-2 – EMC Low frequency harmonic currents ABL 7RE UL, CSA, TÜV, CTick UL 508, CSA 22.
Characteristics (continued) 0 Power supplies 0 Power supplies for d.c.
Output characteristics 0 Power supplies 0 Power supplies for d.c. control circuits Phaseo® regulated switch mode power supplies Derating The ambient temperature is a determining factor which limits the power that an electronic power supply can deliver continuously. If the temperature around the electronic components is too high, their life will be significantly reduced.
Power supplies Output characteristics (continued) 0 0 Power supplies for d.c. control circuits Phaseo® regulated switch mode power supplies Load limit ABL 7CEM24ppp ABL 7RE24pp/ABL 7RPpppp ABL 7Upp24pp/ABL 7REQpppp U out (%) U out 100 % 19 V 50 % 1 2 I out In I out 1,1 x In 1,2 x In 1,2 x In 1 ABL 7RE24pp/ABL 7RPpppp 2 ABL 7Upp24pp/ABL 7REQpppp Temporary overloads ABL 7CEM ABL 7RE/ABL 7RP I out T (ms) 100 90 I out T (ms) 20 I out:(0...100%) I out:(0...
Selection 0 Power supplies 0 Power supplies for d.c.
References 0 Power supplies 0 Power supplies for d.c. control circuits Phaseo® regulated switch mode power supplies 108700-13-M ABL 7CEM single-phase regulated switch mode power supplies 43367-15-M ABL 7CEM Mains input voltage 47...63 Hz V a 100 to 240 single-phase wide range c 110 to 220 (1) Output Nominal voltage power Nominal current cV 24 A 0.3 0.6 1.
Dimensions Power supplies 0 0 Power supplies for d.c. control circuits Phaseo® regulated switch mode power supplies ABL 7RE2405 ABL 7RP1205/2405/4803 120 4.72" 27 1.06" 120 4.72" 54 2.12" ABL 7CEM24006/ ABL 7CEM24012 ABL 7CEM24ppp ABL 7CEM24003 ABL 7RE2410 ABL 7RP2410 120 4.72" ABL 7RE2402/2403 ABL 7RP2403 120 4.72" ABL 7RE24pp/ABL 7RPpppp Common side view Mounting on 35 and 75 mm rails 135 5.31" ABL 7REQ24ppp/ABL 7UEQ24100/ABL 7UES24050/ ABL 7UPS24100 70 2.75" 95 3.74" 127 4.
Schemes 0 Power supplies 0 Power supplies for d.c.
Product Reference Index ABE 9C1240C23 . . . . 8 ABE 9C1240C23 . . . . 9 ABE 9C1240L05 . . . . . 8 ABE 9C1240L05 . . . . . 9 ABE 9C1240L10 . . . . . 8 ABE 9C1240L10 . . . . . 9 ABE 9C1240M . . . . . . 9 ABE 9C1241C23 . . . . 8 ABE 9C1241C23 . . . . 9 ABE 9C1241L05 . . . . . 8 ABE 9C1241L05 . . . . . 9 ABE 9C1241L10 . . . . . 8 ABE 9C1241L10 . . . . . 9 ABE 9C1241M . . . . . . 9 ABE 9C1280C23 . . . . 8 ABE 9C1280C23 . . . . 9 ABE 9C1280L05 . . . . . 9 ABE 9C1280L10 . . . . . 8 ABE 9C1280L10 . . . . .
Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.
Head office Schneider Electric North American Operation Division 1415 South Roselle Road Palatine, IL 60064 TEL 847-397-2600 http://www.us.telemecanique.com http://www.us.schneider-electric.com Owing to changes in standards and equipment, the characteristics given in the text and images in this document are not binding us until they have been confirmed with us. Production : Schneider Electric Industries Photos : Schneider Electric Industries Printed by : MKTED203113EN-US Schneider Electric ART.