2 OMESTIC I N STA L L AT I O N
OMESTIC DOMESTIC INSTALLATION GUIDE 13
Domestic Installation Guide CONTENTS Section 1: Section 2: Appliance Details 1a: Domestic Owner’s Details 15 1b: Installer’s Details 15 1c: Service History 15 Installation Details 2a: 2b: 2c: 2d: 2e: 2f: 2g: 2h: 2i: 2j: 2k: 2l: 2m: 2n: Section 3: Page General Install Requirements 2a1: Location 2a2: Corrosion Protection Air Flow Evaporator Drain Pressure and Temperature Relief (PTR) Valve Expansion Control Valve (ECV) Cold Water Connection Pressure Reducing Valve Caution Regarding Gla
Domestic Installation Guide Section 1: APPLIANCE DETAILS For future convenience, please fill in the following details and retain with your original invoice. 1a: Owner’s Details Surname:....................................................................................................................................................
Domestic Installation Guide Section 2: Installation Details Figure 1A: Installation Diagram (Compact System’s) Recommended That 400mm distance is allowed above the top of the water heater.
Domestic Installation Guide Figure 1B: Basic Tank Layout with Recommended Valves (except Tempering) Figure 1C: domestic Installation Diagram 100mm Min Condensation Drain 500mm Min Power Cord 15° Water Connections Wall 32° 200-500mm PTR Valve Front Access Tank Orientation Diagram for Compact Units (except Compact Titan) Note: If installing multiple Compact units, the orientation of the tank will need to be at 90 degrees to the normal arrangement so that the fan points out from the wall rather than al
Domestic Installation Guide Figure 2: Installation Diagram (SPLIT System’s) Tank Orientation Diagram for Split Units 100mm Min Wall Power Connection 35° Water Connections 200-500mm 32° PTR Valve Front Access Note: The pipes connected to the water heater’s cold water and hot water connections should not be a type that is flexible/soft. All refrigerant piping needs to be installed by a licensed refrigeration mechanic.
Domestic Installation Guide 2a: General Install Requirements This water heater must be installed by a licensed tradesperson, and in accordance with: 1. AS/NZ 3500.4 National Plumbing and Draining Code, Part 4: Hot Water Supply Systems 2. AS/NZ 3500.4.2, National Plumbing and Draining Code, Part 4.2: Hot Water Supply systems – Acceptable Solutions. 3. Other relevant Australian standards, industry or local water supply regulations or codes for mains pressure storage tanks.
Domestic Installation Guide 2d: Pressure and Temperature Relief (PTR) Valve a. The Pressure and Temperature Relief Valve (see tank label for rating), which is supplied with the unit, must be fitted and made accessible so that the release mechanism can be operated and, if required, the valve replaced. b. The outlet of the PTR Valve must be suitably drained to remove the water discharged during the normal heating cycle. The valve thread is RP ½”/15mm and must be installed into the top front socket.
Domestic Installation Guide 2k: Tempering Valves a. The tempering valve should be fitted on the hot water outlet of the Quantum units to reduce water temperature to the temperature designated in (e.g., 50°C as per the plumbing code and Federal, State requirements. b. Quantum recommends the use of high performance valves suitable for “Solar” type water heaters. 2l: Electrical Connection a. Quantum water heaters are designed for single-phase 220-240V 50Hz A.C supply only.
Domestic Installation Guide 2n: Caution Regarding Drilling the Outer Casing This is extremely important and MUST be adhered to without exception! DO NOT DRILL ANY HOLES IN OUTER METAL CASING DRILLING OF ANY HOLES WILL VOID WARRANTY Section 3: Operating Instructions 3a: Filling the Water Heater Open all hot water taps. Open isolating valve at the cold-water inlet and allow the water heater to fill until water flows through the system. Close each hot water tap after the air is expelled from its line.
Domestic Installation Guide Appendix A: Specifications and Dimensions Figure 3: Specifications AND Dimensions C C C A A A B B 70mm 70mm MaSS (Empty (Kg) Model Number Mass (Full) (Kg) 70mm R134a Charge (gm) Dimensions(mm) A B C 975 540 Mass 250 Mass 1650 R134a 1620 Dimensions(mm) (Empty) (Full) Charge 315 1650 1950 1305 540 (Kg) (Kg) (gm) A B C 135 1190 650 100 405 250 1850 1650 19001620 975 540 170 510 1850 2200 1490 650 115 315 1650 1950 1305 540 100 150-08ACW-134 Model Number 200-08AC
Domestic Installation Guide Figure 4: Split Evaporator – FinNED Coil D B D B Air Flow A Air Flow A Discharge Power Cable Refrigeration Line Connection C 3/8 ” Refrigeration Connection C 3/8 ” 5/8” Discharge Line Power Cable 5/8” Suction Line Suction Line 100 110 110 50 Model 40 50 150 Dimensions (mm) A B Model C D 150/200-08ASW-134 440 445 445 310 270/340-11AS4-134 340-17ASW-134 (340TIH-134) 440 510 485 330 500 635 660 440 150/200-08ASW-134 270/340-11AS4-134 340-
Domestic Installation Guide Figure 6: Wiring Diagram: 150/200-08ASW-134 & 340-17ASW-134 (340-TIH-134) Figure 7: Wiring Diagram: 340-17ACW-134 25
Domestic Installation Guide Figure 8: Indicator 340-17ACW-134 Indicator light Figure 9: Wiring Diagram – With Timer: 150/200-08ACW-134 & 270/340-11AC4-134 26
Domestic Installation Guide Figure 10: Wiring Diagram – With Timer: 150/200-08ASW-134 & 270/340-11AS4-134 AS2712 LIC.
NOTES ���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ������������������������������������������������������������������������������������������������������������������������������������������������
NOTES ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� �������������������������������������������������������������������������������������������������������������������������������������������������
PERFORATION – PLEASE DO NOT PRINT Delivery Address: PO Box 553 SYDNEY NSW 2012 Quantum Energy Technologies Reply Paid 553 Strawberry Hills NSW 2012 30