Installation guide
54
FIGURE 4: HYDRONIC CONNECTION FOR 340-17ACW3-134
COMMERCIAL INSTALLATION GUIDE
When installing a single Titan Compact unit the intake fan should always point out from, or along the wall.
If the cold air discharge fan is facing towards a wall, the suggested distance between the unit and the wall is *500mm.
Multiple installations of Titan Compacts must be plumbed in using an “Equal Flow Manifold System” failure to do so
may void warranty.
When installing multiple Titan Compact units, the fan should never face towards the adjacent unit.
(Cold discharge fan to ambient air intake fan) this would reduce the efficiency of the units.
*The space between multiple units should be a minimum of 200mm for air flow, where possible 500mm is suggested
for the convenience of service. See schematic above.
*If the distance is less than 500mm off a wall the use of “Baffle” panels may be necessary. Baffles are positioned along
the top and between the units to assist the cold air discharge downwards to prevent cold air bouncing back into the
ambient air intake.
If you have any questions in regards to installation please contact your local Quantum office or call 1800 644 705
for assistance.
Cool Air Discharge
*Suggested Minimum
Distance of 200mm
between Tanks
Red “Alert” Lamp to face
out from wall
*Suggested Distance
from any Wall
500mm
Ambient Air Flow
0001_QEco_D_C_LC_Owners_Manual_Warranty_A4_Spreads_72pp.indd 54 11/04/12 11:41 AM