Quantum Energy Technologies Owner’s Manual OWNER'S MANUAL Including Installation Instructions And Warranty Information TO SUIT HEAT PUMP STORAGE WATER HEATER MODELS Compact: Split: 150-08ACW-134 200-08ACW-134 270-11AC3-134 340-11AC3-134 270-11AC4-134 340-11AC4-134 340-17ACW-134 150-08ASW-134 200-08ASW-134 270-11AS4-134 340-11AS4-134 340-17ASW-134 (340TIH-134) (with Recommended Connections for Commercial Models) FOR ADVICE, REPAIRS AND SERVICE Australia: 1800 644 705 New Zealand: 0800 402 002 Document
Owner’s Manual Quantum Energy Technologies Contents Section 1: APPLIANCE DETAILS ……………………………………………………………………….. 5 1a: Owner’s Details ………………………………………………………………………………. 5 1b: Installer’s Details 1c: Service History …………………………………………………… 5 Section 2:INTRODUCTION ……………………………………………………………………. 2a: One Of The World’s Most Energy Efficient Methods Of Water Heating ………………. 2b: Time Delay On Start …………………………………………………………………….. 2c: Features Of Your Quantum Water Heater ……………………………………………………...
Owner’s Manual Quantum Energy Technologies Section 6: MAINTAINANCE & SERVICE INFORMATION................................................. 6a: The Water Tank .................................................................................................................. 6b: Air Evaporator Coils........................................................................................................... 6c: Sacrificial Anode ....................................................................................
Owner’s Manual Quantum Energy Technologies Appendix A: TROUBLE SHOOTING GUIDE ON QUANTUM WATER HEATERS .......... A.1: No Hot Water; Compressor Not Running ........................................................................ A.2: Thermal Cut Out Trips Off Repeatedly ............................................................................ A.3: No Hot Water; Compressor Running ............................................................................... A.4: Shortage Of Hot Water .................
Owner’s Manual Quantum Energy Technologies Section 1: APPLIANCE DETAILS For future convenience, please fill in the following details and retain with your original invoice. 1a: Owner’s Details Surname: …………………………………… Given Name(s): ….……………………….... Address: ……………………………………………………………………………...………… Town/Suburb: ……………………………………………………………………..…………… State/Territory:……………………………… Postcode: …………………………………… Date of Purchase: .….……….……………… Purchased From: ………………………………………..………………………………….…… Model: ..……………………………………..
Quantum Energy Technologies Owner’s Manual Section 2: INTRODUCTION QUANTUM ENERGY TECHNOLOGIES 2a: One Of The World’s Most Energy Efficient Methods Of Water Heating Production We thank you for your decision to purchase a Quantum Energy Technologies Heat Pump Water Heater, which will reward you with many years of low energy hot water production. QUANTUM ENERGY TECHNOLOGIES Pty Ltd designs and manufactures energy efficient heat pump water heaters.
Quantum Energy Technologies Owner’s Manual Warranty Return Card Enclosed you will find a warranty card – please fill in the details and return to Quantum. This will ensure prompt service under warranty, if required (see Section 8 for terms of warranty). Section 3: INSTALLATION DETAILS 3a: General Installation Requirements This water heater must be installed by a licensed tradesperson, and in accordance with 1. AS 3500.4, National Plumbing And Drainage Code, Part 4: Hot Water Supply Systems. 2. AS 3500.
Owner’s Manual Quantum Energy Technologies acceptable. The separate evaporator in the split models could be located externally or in a large well-ventilated ceiling space or garage. 3c: Evaporator Drain During operation a certain amount of condensate water will flow from the evaporator drain. If allowed to simply flow out of the outlet, this water may pool below the unit and can cause problems to the water heater and/or area around it.
Quantum Energy Technologies Owner’s Manual Figure 1: Installation Diagram (Compact Systems) Thermo Siphon Trap 100 mm Min Orientation if multiple Compact units are being installed. Wall Condensation Drain 500 mm Min Power Cord 15° Water Connections 32° i.e. fan to face out. 200-500 mm PTR Valve Front Access 1. 2. 3. 4. NOTE: In installing single Compact units, the fan should point out from, or along, the wall.
Quantum Energy Technologies Owner’s Manual Figure 2: Installation Diagram (Split Systems) 100 mm Min Wall Power Connection 35° Water Connections 200-500 mm 32° PTR Valve … Front Access Note: The pipes connected to the water heater’s cold water and hot water connections should not be the flexible/soft type. Document number: QDC0030PD-16.
Owner’s Manual Quantum Energy Technologies 3j: Draining Of Tank Consideration should be given to the possible necessity of draining the tank at some point. Draining of the tank can be accomplished by the connection of a hose to the cold water inlet and running to a suitable drain. It will be necessary to disconnect the hot water outlet or PTR valve to relieve any partial vacuum created as the water flows out.
Quantum Energy Technologies Owner’s Manual 3n: Refrigeration Connections (Split Models Only) Refrigeration pipe work is very specialized and should only be completed by a licensed tradesperson. Maximum refrigeration pipe length from the tank connections to the evaporator is 9m. If the evaporator is mounted below the tank connection point, then a suitable oil trap needs to be installed on the suction line between the evaporator and the heat pump. 3n.
Owner’s Manual Quantum Energy Technologies Section 5: SAFETY INFORMATION DO NOT TURN ON POWER UNLESS THE TANK IS FULL OF WATER 5a: Safety Devices WARNING: For safe performance this water heater is fitted with: 1. Digital Controller. 2. A thermostat (connected to the digital controller) to manage water temperature. 3. A thermostat (connected to the digital controller) to manage compressor temperature. 4. A non self-setting thermal cut out (incorporated into the digital controller). 5.
Quantum Energy Technologies Owner’s Manual 6b: Air Evaporator Coils Quantum water heaters use evaporator coils to extract heat from the air. The coil is extremely efficient in warm humid weather; however, as temperatures drop to ten degrees or less the coil will begin to collect ice. The coil has been designed with "heat injection" to defrost the coil under such conditions. The heat injection cycle is automatic and is managed by the digital controller.
Owner’s Manual Quantum Energy Technologies It is very important that the mechanism is operated gently. Check to ensure the valve closes correctly. Note: providing some hot water discharge has been observed from the relief valve during normal heating cycles, manually activating the valve is not necessary and could cause contamination / grit to lodge in the relief valve seat causing constant leakage.
Owner’s Manual Quantum Energy Technologies 3. Remove the blanking plug (brass fitting) from the unused inlet (normally on the right hand side for left hand connected tanks) – the inlets are at the bottom of the tank 70mm up from the base. 4. Remove the blanking plug from the unused hot water outlet (normally on the right hand side for left hand connected tanks) – the outlets are at the top of the tank. 5.
Owner’s Manual Quantum Energy Technologies can be quite common – Off Peak tariffs are not recommended for Quantum water heaters. 2. Check that the thermal overload (on the digital controller) has not been tripped. If so press the “Set” button (hold for 6 seconds) to reset it. 3. Is the Pressure & Temperature Relief valve discharging too much water? See Section 7a: "Pressure & Temperature Relief Valve Running". 4.
Quantum Energy Technologies Owner’s Manual THE WARRANTY SHALL NOT APPLY IN ANY OF THE FOLLOWING EVENTS: 1. The unit is installed by an non licensed Plumber with inadequate technical skills or training to perform the task; 2. The installer does not issue a Plumber’s Certificate of Compliance in the State of Victoria. (State Rebate’s in Victoria will not be paid unless a Certificate of Compliance number is provided). 3.
Owner’s Manual Quantum Energy Technologies □ Cleaning / maintenance of the water heater unit. □ Calls made to check the operation of a unit, which is found to be working satisfactorily. □ Remounting or relocating equipment due to ground subsidence. □ Modifications to system after installation due to changes in requirements. □ Relocation of equipment due to complaints of noise level or inappropriate location.
Quantum Energy Technologies Owner’s Manual Section 9: SPECIFICATIONS Figure 3: Specifications & Dimensions C C C A A A B B B 70mm Model Number 150-08ACW-134 200-08ACW-134 270-11AC3/4-134 340-11AC3/4-134 340-17ACW-134 150-08ASW-134 200-08ASW-134 270-11AS4-134 340-11AS4-134 340-17ASW-134 (340TIH-134) 70mm 70mm Mass (Empty) (Kg) Mass (Full) (Kg) R134a Charge (gm) 100 115 250 315 135 170 190 90 105 120 155 165 Dimensions(mm) Power Input (W) Nominal Capacity (Lt) 660 660 125 175 1650 16
Quantum Energy Technologies Owner’s Manual Figure 4: Split Fin Coil Evaporators D B Air Flow A Refrigeration Connection C Power Cable Refrigeration Connection 100 110 50 150 40 Dimensions (mm) Model A B C D 150/200-08ASW-134 440 445 445 310 270/340-11AS4-134 340-17ASW-134 (340TIH-134) 440 510 485 330 500 635 660 440 A qualified refrigeration technician must install the Split Air model.
Owner’s Manual Quantum Energy Technologies Section 10: OPERATION & ADJUSTMENT OF THE DIGITAL CONTROLLER Caution: Alteration of the Digital Controllers programming & settings without authorisation from Quantum Energy Technologies will void your warranty. This section is provided ONLY for qualified refrigeration technicians to assist in servicing, repairs or trouble shooting. 10a: The Buttons Use In Conjunction With The Layout Diagram Fig:5 And Wiring Diagrams Fig: 6&7&8&10&11. 10a.
Owner’s Manual d05 H95 L70 P85 b75 F08 C-5 Quantum Energy Technologies Temperature difference for heat pump reactivation (H55 - d05=50℃) 5 to 30℃ adjustable. Factory setting 5℃. Overheat trip-out temperature; 60 to 98℃ adjustable. Factory setting 95℃. Overheat reset temperature; 60 to 98 adjustable. Factory setting 70℃. Liquid Injection activation temperature; 55 to 98℃ adjustable. Factory setting 85℃. Liquid Injection de activation temperature; 55 to 98℃ adjustable. Factory setting 75℃.
Owner’s Manual Quantum Energy Technologies activated and the error code E05 will be displayed. When the compressor temperature drops below 70℃ (2nd Level L70), and the compressor has not been in operation for at least 10 min (1st Level d10), the compressor will be reactivated. As the compressor temperature goes above 105℃, the compressor will be de activate and the error code E06 will be displayed. A manual reset is required.
Owner’s Manual Quantum Energy Technologies Fig 6: Wiring Diagram--150/200-08ACW-134 & 270/340-11AC3-134 Fig 7: Wiring Diagram--150/200-08ASW-134 & 340-17ASW-134(340TIH-134) Document number: QDC0030PD-16.
Quantum Energy Technologies Owner’s Manual Fig8: Wiring Diagram- 340-17ACW-134 Fig 9: Fault Indicator- 340-17ACW-134 Indicator light Document number: QDC0030PD-16.
Owner’s Manual Quantum Energy Technologies Fig 10: Wiring Diagram-with Timer--150/200-08ACW-134 & 270/340-11AC4-134 Fig 11: Wiring Diagram-with Timer--150/200-08ASW-134 & 270/340-11AS4-134 Document number: QDC0030PD-16.
Quantum Energy Technologies Owner’s Manual Appendix A: TROUBLE SHOOTING GUIDE ON QUANTUM WATER Models covered in this guide: 800 Watt. 1100 Watt. 1700 Watt. Compact and Split Air Source Domestic Hot Water Heater (0.8kW compressor models): 150/200-08ACW-134; 150/200-08ASW-134 Compact and Split Air Source Domestic Hot Water Heaters (1.1kW compressor models): 270/340-11AC3-134; 270/340-11AC4-134; 270/340-11AS4-134 Titan and Split Compact & Split Air Source Hot Water Heaters (1.
Quantum Energy Technologies Owner’s Manual 4. Compressor runs hot: Internal leakage. High superheat. Find out and fix the leaking spot and charge the right amount of gas. Open TX valve 1/4 each step and have a observation. Replace TX valve. Check for refrigerant over charge, TX valve open too much, compressor winding resistance or mechanical fault in the compressor rotors or valves. Adjust gas charge if needed. Close TX valve if needed, or replace compressor if it is faulty.
Quantum Energy Technologies Owner’s Manual A. 4: Shortage Of Hot Water Probable Cause 1. System under sized. 2. Unexpected load or weather condition. Test / Observation Check actual load with design load. a. Check for excessive hot water draw. b. Check for not water leakage. c. Check heat loss if the heater is on reticulation circuit. Action Re-size. a. Re-size if extra hot water draw is to be included in the design. b. Repair leakage if found. c.
Quantum Energy Technologies Owner’s Manual A.8: Signs Of Correct Charge During normal operation with the correct amount of refrigerant gas, the sight glass should show clear liquid. A very few small bubbles may be present when the system is started or when the TX valve opens quickly. But it should return to clear liquid shortly after. Current draw and delivery pressure will be within the nominal range and temperatures should be consistent with gas properties.
Quantum Energy Technologies Owner’s Manual Appendix B: RECOMMENDED CONNECTIONS FOR COMMERCIAL MODELS Figure B1: Hydronic Connection for 340-17ACW3-134 Hot Water Out DN25 DN20 DN20 DN20 Titan Titan Titan DN20 DN20 DN20 DN25 Item Item Description Cold Water In Description Isolating Valve Cold Water Non Return Valve Hot Water Rubber Flexble Connection Pressure Limiting Valve *1 Expansion Control Valve TIPS: 1.
Quantum Energy Technologies Owner’s Manual WARRANTY CARD Product Model: Serial Number: End User Details First Name Last Name Installed Address City Phone State Work Phone P.C. Country Mobile Fan Coil Evaporator Refrigeration (Split System) Air Box vs Heat Pump …□Above □Below Location (i.e. Outdoor / Indoor) Oil Trap Created ……….□ Yes Evaporator Ventilation ………. □Good □Poor Refrig. Tube Length in Vertical M Refrig. Tube Length m Air Flow Unrestriction Air discharge facing wall …..
Owner’s Manual BLANK PAGE Document number: QDC0030PD-16.
Owner’s Manual Quantum Energy Technologies NOTES (Owner’s Use) Document number: QDC0030PD-16.
Quantum Energy Technologies Owner’s Manual QUANTUM ENERGY TECHNOLOGIES PTY LTD 56-60 Bourke Road Alexandria NSW 2015 AUSTRALIA. A.B.N: 88 095 959 327 Phone: (+61 2) 9699 7444 Fax (61 2) 9699 5386 18b Tarndale Grove, Albany, Auckland, New Zealand Phone: (+64 9) 443 6354 Fax (64 9) 443 6356 NOTE: Every care has been taken to ensure the accuracy in preparing this publication. No liability can be accepted for any consequences, which may arise as a result of its application.