User's Guide

Installing the Autoloaders Installing the Internal Autoloader
23
Figure 5. DIP-Switch Settings for the Internal Autoloader
Data Compression (switches 1 and 2)
Switch 1 enables or disables hardware data compression. Switch 2 determines whether SCSI
commands can be used to enable or disable hardware data compression.
Switch 1 ON: Hardware data compression is enabled when drive is powered on. (default)
Switch 1 OFF: Hardware data compression is disabled when drive is powered on.
Switch 2 ON: SCSI commands can be used to enable or disable hardware data
compression (default)
Switch 2 OFF: SCSI commands cannot be used to enable or disable hardware data
compression
Media Recognition System (switch 3) - DDS-4 autoloader only
The Media Recognition System (MRS) allows the drive to determine whether a given tape cartridge
conforms to the DDS tape standard. Switch 3 determines how the drive works with MRS and non-
MRS media. Using non-DDS media may appear to give satisfactory results, but the inferior
specifications of such media can cause data-integrity problems.
Switch 3 ON: Drive reads from and writes to MRS media, and reads from but does not write
to non-MRS media (default)
Switch 3 OFF: Drive reads from and writes to both MRS and non-MRS media.
Power On Self Test Enable/Disable (switch 4)
Switch 4 enables or disables execution of Power On Self Test (POST) diagnostics when the drive is
powered on.
Switch 4 ON: Drive performs POST when powered on. (default)
Switch 4 OFF: Drive does not perform POST when powered on.
Data compression (DC)
SCSI DC control
Media recognition
Self Test
Wide/Narrow SCSI
Inquiry String support
1
2
3
4
5
6
7
8
9
10
O
N
Default settings shown
Operating-system
configuration
switches
Data compression (DC)
SCSI DC control
Media recognition
Self Test
Wide/Narrow SCSI
Inquiry String support
Operating-system
configuration
switches
O
N
Default settings shown