Technical data

Placing the DLT2500XT Stacker
45
Placing the DLT2500XT Stacker
After you have set the stackers SCSI ID, you are ready to install the desktop DLT2500XT
stacker.
After placing the DLT2500XT stacker in its intended location, go on to the following
sections for information on connecting the SCSI cable and power cord properly.
You can position the stacker
on a work surface area near the host system
on top of the Challenge or Onyx deskside chassis
Caution: Do not stand the DLT2500XT stacker on its side and do not place it on the
oor or on top of a rack system.
Connecting the DLT2500XT Stacker to the Host
To obtain the best performance from your DLT2500XT stacker, connect the unit as the
only device on the SCSI bus. Use the following procedures to properly connect your
DLT2500XT stacker to the host system:
1. Power off the host system.
2. Plug one end of the SCSI cable into the hosts external SCSI connector. On Challenge
and Onyx deskside and rackmount systems, the differential SCSI connector is
located on the I/O panel behind the door, as shown in Figure 4-2 and Figure 4-3.
Note: The DLT2500XT stacker is a differential SCSI device only and must be
connected to a differential bus.