Technical data
Updating Firmware From a Tape Cartridge
79
Updating Firmware on Sled-Mounted and Desktop DLT2000XT Tape
Drives
Follow these steps:
1. Make sure tape operations are finished. For the firmware update to be successful,
the drive must have passed the power-on self-test (POST).
2. Remove any cartridge in the DLT2000XT tape drive and close the load/unload
handle.
3. Press down and hold the Unload button for about six seconds until the Write Protect
LED blinks. This indicates that the drive subsystem has recognized your request for
firmware update mode and is waiting for the sequence to complete.
If the Write Protect LED does not blink, make sure that
• the drive passed the POST
• the drive is unloaded
• the drive handle is in the down position
4. Release the Unload button. Immediately (within four seconds) press it again, for less
than one second.
The Write Protect and Tape in Use LEDs blink, indicating that the drive subsystem
recognizes that firmware update mode has been selected.
If selecting the firmware update mode is not successful, the Write Protect LED stops
blinking within several seconds. Try the procedure again. If the drive and controller
are not communicating properly, you cannot select firmware update.
5. Once you have successfully selected firmware update mode, load the update
cartridge into the drive. The Write Protect and Tape in Use LEDs temporarily go
dark as the DLT2000XT tape drive reads the tape and examines the new firmware
data. Calibration and directory processing cause the tape to move for a few minutes
before data is actually read.
Caution: Never turn off power to the DLT2000XT tape drive while the firmware is
being updated. Doing so interrupts the update process, and can damage the unit.
The drive automatically verifies that the data is a valid DLT2000XT firmware
upgrade. Firmware update mode is automatically cleared at this point.