User`s guide

Quantum DLT Drives & Media
Troubleshooting DLT Drives
Chapter 22-16
DLT Cleaning Issues
Table 2-3 describes situations you may encounter with cleaning
cartridges and how to resolve them.
Table 2-3 DLT Cleaning Issues
Problem Solution
Recurring cleaning
message.
If the message reappears after
cleaning the drive, the front panel
display will indicate the need to
replace the cleaning cartridge.
Replace the existing cleaning
cartridge with a new one.
If the message reappears when a
particular data cartridge is used,
verify that the data cartridge is
readable by:
Clearing the error message.
Reading the tape again.
If the data cartridge can be read,
backup data from the damaged
cartridge to another cartridge, and
discard the damaged one.
A brand new data
cartridge is used and the
clean drive icon is
displayed.
Clean the outside of the data
cartridge using a damp cloth.
Clean the drive using the drive
cleaning procedure in your tape
library or autoloader user’s guide.
If the icon is displayed again within a
short amount of time, replace the
data cartridge.
Cannot load the cleaning
cartridge.
Ensure the cleaning cartridge
matches your drive type. Cleaning
cartridges are unique for each drive
technology.