ACO Bathroom Drainage Installation Guide
Technical & planning considerations Accumulation and slopes ASME A112.6.3-2001 requires a 2“ outlet for shower applications. QuARTz by ACO channels have this as standard. The flow value for a 2" outlet varies depending upon the head of water above the grating. In the case of shower channels, a head of water is not typical in practice, due to shallower floor grades. Floor drains can have a head of water due to ‘basin’ profile of floor grades.
Drainage planning information Linear drainage options Installation against the wall Walk-through: installation against the wall Walk-in: installation against the wall Simplest slope solution in one direction – slope away from the bathroom – no risk of bypass – use of CPE flexible membrane is recommended. Slope in one direction – just shower area or whole bathroom floor can be sloped towards channel – use of CPE flexible membrane is recommended.
Installation overview Plain body Tiled showers rely on waterproofing membrane beneath the tiles and grout. QuARTz by ACO offers a number of options to ensure compatibility with different floor structures. Stainless steel channel The installation details shown set out to provide the designer with integrated solutions to wet room floor drainage identifying preparation, installation and construction processes required to install waterproof channels and floor drains in level threshold wet room environments.
1. Flange body Stainless steel grate Box out detail showing suggested dimensions. Liquid membrane (supplied by others) 2. Stainless steel channel After removing box formwork connect shower channel to plumbing pipe work. Membrane clamp Height adjustable leveling feet 3. Compression fit gasket Shower channel fitted in place prior to final concrete slurry pour. Shower channel flange should be at same level as original concrete slab.
Installation overview Point Drain Tiled showers rely on waterproofing membrane beneath the tiles and grout. QuARTz by ACO offers a number of options to ensure compatibility with different floor structures. The installation details shown provide the designer with integrated solutions to wet room floor drainage identifying preparation, installation and construction processes required to install waterproof channels and floor gullies in level threshold wet room environments.
Product Cleaning Instructions DO USE: • A solution made from mild soap or dish detergent & warm water • A soft, clean cotton cloth • Clean water to rinse then wipe dry • Baking soda & water paste to remove oxidized stains and surface rust DO NOT USE: • Cleaning agents containing chlorides, alcohol, ammonia, alkaline or mineral spirits • Steel wool or wire brushes • Abrasive cleaners 7
Other ACO systems ACO DRAIN ACO Drain is the world’s leading modular trench drain system for commercial, industrial and landscape applications. ACO SPORT Surface drainage and building accessories for track & fields, used at Olympic sites since 1972. AQUADUCT Custom designs and manufactured fiberglass trench drain systems to meet individual project requirements. ACO INFRASTRUCTURE Surface drainage products engineered for the unique design and performance demands of highways, urban roads and bridges.