Installation manual
CM-4221 Installation Manual 
72 
  Send HTTP notification 
Check this box to specify the destination HTTP address and parameters for event 
notifications by the triggered alarm. When an alarm is triggered, the notification 
will be sent to one of two specified HTTP servers.  
File Name  
  File Name 
Enter a file name in the field, for example, “image.jpg”. The uploaded image’s 
file name format is set in this section. Select one that meets your requirements. 
  Add date/time suffix 
File name: imageYYMMDD_HHNNSS_XX.jpg 
Y: Year, M: Month, D: Day 
H: Hour, N: Minute, S: Second 
X: Sequence Number 










