Specifications

GV300 @Track Air Interface Protocol
3.2.8. External Power Supply Monitoring
The command AT+GTEPS is used to configure the parameters of external power supply
monitoring. The device will measure and monitor the voltage of the external power supply. If the
voltage of the external power supply matches the predefined alarm condition, the device will
report an alarm message +RESP:GTEPS to the backend server to notify the status of the external
power supply.
To make sure this function works in all situations, please switch on the internal backup battery in
case that the voltage of the external power supply may drop very low.
¾ AT+GTEPS=
Example:
AT+GTEPS=gv300,2,250,12000,3,2,1,1,0,0,1,,,,0007$
Parameter Length(byte) Range/Format Default
Password 4 – 6 '0' – '9' 'a' – 'z' 'A' – 'Z' gv300
Mode 1 0|1|2 0
Min Threshold <=5 250 – 28000 mV
Max Threshold <=5 250 – 28000 mV
Sample Period <=2 0|1 – 12(×2s) 0
Debounce Time 1 0 – 5 (×1s) 0
Output ID 1 0 – 3
Output Status 1 0|1
Duration <=3 0 – 255(×100ms) 0
Toggle Times <=3 0 – 255 0
Sync with FRI 1 0|1 0
Reserved 0
Reserved 0
Reserved 0
Serial Number 4 0000 – FFFF
Tail Character 1 $ $
<Mode>: Working mode of the external power supply monitoring.
z 0: Disable the external power supply monitoring.
z 1: Enable the external power supply monitoring. If the current voltage is within the
range of (<Min Threshold>, <Max Threshold>), the +RESP:GTEPS alarm will be
triggered.
TRACGV300AN002 27
Queclink