Specifications

GV300 @Track Air Interface Protocol
3.2.12. Tow Alarm Configuration
The AT+GTTOW command is used to configure the motion sensor and the parameters for tow
alarm.
¾ AT+GTTOW=
Example:
AT+GTTOW=gv300,1,5,0,120,1,0,5,10,4,10,4,,,,,,,,,000B$
Parameter Length(byte) Range/Format Default
Password 4 – 6 '0' – '9' 'a' – 'z' 'A' – 'Z' gv300
Tow Enable 1 0|1 0
Engine Off to Tow <=2 5 – 15 min 10
Fake Tow Delay <=2 0 – 10 min 1
Tow Interval <=5 30 – 86400 sec 300
Tow Output ID 1 0 – 3
Tow Output Status 1 0|1
Tow Output Duration <=3 0 – 255 (×100ms) 0
Tow Output Toggle Times <=3 0 – 255 0
Rest Duration <=3 0 – 255 (×15sec) 2
Motion Duration <=2 0 – 10 (×100ms) 3
Motion Threshold 1 2 – 4 2
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Serial Number 4 0000 – FFFF
Tail Character 1 $ $
<Tow Enab le>: Enable or disable tow alarm (+RESP:GTTOW).
TRACGV300AN002 37
Queclink