User's Manual

LTE Module Series
EC25-V User Manual
EC25-V_User_Manual Confidential / Released 55 /
69
Table 30: Conducted RF Output Power
Frequency
Max.
Min.
LTE FDD B4/B13
23dBm±2dB
<-44dBm
6.6. RF Receiving Sensitivity
This information will be added in future version of this document.
6.7. Electrostatic Discharge
The module is not protected against electrostatics discharge (ESD) in general. Consequently, it is subject
to ESD handling precautions that typically apply to ESD sensitive components. Proper ESD handling and
packaging procedures must be applied throughout the processing, handling and operation of any
application that incorporates the module.
The following table shows the module electrostatics discharge characteristics.
Table 31: Electrostatics Discharge Characteristics
Tested Points
Contact Discharge
Air Discharge
Unit
VBAT, GND
±5
±10
kV
All Antenna Interfaces
±4
±8
kV
Other Interfaces
±0.5
±1
kV