Product Info

Table Of Contents
LTE Module Series
EG61-NA Hardware Design
EG61-NA_Hardware_Design 28 / 77
RXD
TXD
RI
DTR
AP_READY
TXD
RXD
EINT
GPIO
GPIO
Module
Host
GND
GND
Figure 3: Sleep Mode Application via UART
Driving the host DTR to low level will wake up the module.
When EG61-NA has a URC to report, RI signal will wake up the host. Refer to Chapter 3.16 for
details about RI behavior.
AP_READY will detect the sleep state of host (can be configured to high level or low level detection).
Please refer to AT+QCFG="apready"*commandfor details.
“*” means under development.
3.5.1.2. USB Application with USB Remote Wakeup Function
If the host supports USB suspend/resume and remote wakeup functions, the following three preconditions
must be met to let the module enter into sleep mode.
Execute AT+QSCLK=1commandto enable the sleep mode.
Ensure the DTR is held at high level or keep it open.
The host’s USB bus, which is connected with the module’s USB interface, enters into suspended
state.
The following figure shows the connection between the module and the host.
NOTE