Voltage drop during
burst transmission
Maximum power control
level on LTE
400 mV
I
VBAT
Peak supply current
(during
transmissionslot)
Maximum power control
level on LTE
A
USB_VBUS
USB connection
detection
3.0 5.0 5.25 V
6.3. Operation and Storage Temperatures
The operation and storage temperaturesare listed in the following table.
Table 29: Operation and Storage Temperatures
Parameter Min. Typ. Max. Unit
Operation Temperature Range
1)
-35 +25 +75 ºC
ExtendedTemperatureRange
2)
-40 +85 ºC
Storage Temperature Range -40 +90 ºC
1.
1)
Within operation temperature range, the module is 3GPP compliant.
2.
2)
Within extended temperature range, the module remains the ability to establish and maintain a
voice, SMS, data transmission, emergency call, etc. There is no unrecoverable malfunction. There
are also no effects on radio spectrum and no harm to radio network. Only one or more parameters
like P
out
might reduce in their value and exceed the specified tolerances. When the temperature
returns to the normal operation temperature levels, the module will meet 3GPP specifications again.
NOTES