Product Info
LTE Module Series
AG35-QuecOpen
Hardware Design
AG35-QuecOpen_Hardware_Design 97 / 137
tolerances. When the temperature returns to normal operation temperature levels, the module will
meet 3GPP specifications again.
3.
3)
Within eCall temperature range, the emergency call function must be functional until the module is
broken. When the ambient temperature is between 75°C and 90°C and the module temperature has
reached the threshold value, the module will trigger protective measures (such as reduce power,
decrease throughput, unregister the device, etc.) to ensure the full function of emergency call.
6.4. Current Consumption
Table 54: AG35-CE Current Consumption (25°C, 3.8V Power Supply)
Parameter Description Conditions Typ. Unit
I
VBAT
OFF state
Power down 20 uA
Sleep state
AT+CFUN=0 (USB disconnected)
1.2 mA
GSM DRX=2 (USB disconnected) 2.3 mA
GSM DRX=9 (USB disconnected) 1.8 mA
WCDMA PF=128 (USB disconnected) 1.8 mA
WCDMA PF=512 (USB disconnected) 1.5 mA
LTE-FDD PF=128 (USB disconnected) 2.1 mA
LTE-FDD PF=256 (USB disconnected) 1.7 mA
LTE-TDD PF=128 (USB disconnected) 2.2 mA
LTE-TDD PF=256 (USB disconnected) 1.7 mA
Idle state
GSM DRX=5 (USB connected) 20 mA
GSM DRX=5 (USB disconnected) 34.0 mA
WCDMA PF=64 (USB connected) 35.0 mA
WCDMA PF=64 (USB disconnected) 22.0 mA
LTE-FDD PF=64 (USB connected) 35.0 mA
LTE-FDD PF=64 (USB disconnected) 22.0 mA