Product Info

Automotive Module Series
AG35 Hardware Design
AG35_Hardware_Design 91 / 129
tolerances. When the temperature returns to normal operation temperature levels, the module will
meet 3GPP specifications again.
3.
3)
Within eCall temperature range, the emergency call function must be functional until the module is
broken. When the ambient temperature is between 75°C and 90°C and the module temperature has
reached the threshold value, the module will trigger protective measures (such as reduce power,
decrease throughput, unregister the device, etc.) to ensure the full function of emergency call.
6.4. Current Consumption
Table 49: AG35-CE Current Consumption (25°C, 3.8V Power Supply)
Parameter
Description
Conditions
Typ.
Unit
I
VBAT
OFF state
Power down
20
uA
Sleep state
AT+CFUN=0 (USB disconnected)
1.2
mA
EGSM900 DRX=2 (USB disconnected)
2.3
mA
EGSM900 DRX=5 (USB disconnected)
1.9
mA
EGSM900 DRX=5 (USB suspend)
2.2
mA
EGSM900 DRX=9 (USB disconnected)
1.6
mA
DCS1800 DRX=2 (USB disconnected)
1.8
mA
DCS1800 DRX=5 (USB disconnected)
1.4
mA
DCS1800 DRX=5 (USB suspend)
1.8
mA
DCS1800 DRX=9 (USB disconnected)
1.1
mA
TD-SCDMA B34
DRX=6 (USB disconnected)
2.0
mA
TD-SCDMA B34
DRX=6 (USB suspend)
2.1
mA
TD-SCDMA B34
DRX=7 (USB disconnected)
1.8
mA
TD-SCDMA B34
DRX=8 (USB disconnected)
1.6
mA
TD-SCDMA B34
DRX=9 (USB disconnected)
1.5
mA