Product Info
 Smart  Wi-Fi  Module  Series 
  SC20-WL  Hardware  Design 
SC20-WL_Hardware_Design                                                            71 / 81 
6.3. Charging Performance Specifications 
Table 32: Charging Performance Specifications 
6.4. Operation and Storage Temperatures 
The operation temperature is listed in the following table. 
Table 33: Operation Temperature 
Parameter 
Min. 
Typ. 
Max. 
Unit 
Trickle charging-A current 
81 
90 
99 
mA 
Trickle charging-A threshold voltage range (15.62mV stepping up)   
2.5 
2.796 
2.984 
V 
Trickle charging-B threshold voltage range (18.75mV stepping up) 
3.0 
3.2 
3.581 
V 
Charge voltage range (25mV stepping up) 
4 
4.2 
4.775 
V 
Charge voltage accuracy 
+/-2 
% 
Charge current range (90mA stepping up)   
90 
1440 
mA 
Charge current accuracy 
+/-10 
% 
Charge termination current: when charge current is from 90 to 450mA 
7 
% 
Charge termination current: when charge current is from 450 to 
1440mA 
7.4 
%  
Parameter 
Min. 
Typ. 
Max. 
Unit 
Operation temperature range   
-35 
+25 
+65 
°C  
Extended temperature range   
-40 
+75 
°C  
Storage temperature range 
-40 
90 
°C  