Installation Guide

LMU-2x20 Hardware and Installation Guide
V1.0.10 December 12, 2010
Copyright ©Calamp Wireless Networks Inc 2010 - 49 - CalAmp Proprietary & Confidential
4.5.3 Inbound Verification
The last item to verify is that the LMU-2x30 is sending data to the correct server. In
general, this is a two-step process that will need the aid of an observer on the back end. That
is, a technician will have to be logged in so they can monitor data coming into the backend
mapping/vehicle management application.
First, verify that the LMU-2x30 is using the correct Inbound IP address by using:
AT$APP INBOUND?
The response should be similar to:
INBOUND LMD
INBOUND 0 ADDR ddd.ddd.ddd.ddd:ppppp *
INBOUND 0 URL myURL.myCompany.com
INBOUND 1 ADDR 0.0.0.0:20500
INBOUND 1 URL
INBOUND 2 ADDR 0.0.0.0:20500
INBOUND 3 ADDR 0.0.0.0:20500
The installer will need to verify with a backend technician that the, URL
(myURL.myCompany.com ), IP address (ddd.ddd.ddd.ddd) and port (<ppppp>) are correct.
The second step is to verify that the LMU-2x30 is sending data. The best way to do this is
to force the LMU-2x30 to send in an unacknowledged Event Report (i.e., its current GPS
location) with the following command:
AT$APP PEG SUNRPT 255
The LMU-2x30 will respond with: OK
The backend monitor must then be contacted to confirm that they received an Event Report
with Event Code 255.
Assuming that all three sections have passed, the installation can be considered to be
complete.