EdgeMarc EdgeMarc 6000 Software Release: Document Revision: Published: 1.0 1.0 05 December, 2019 https://ribboncommunications.
Confidential and Proprietary. Copyright © 2019 Ribbon Communications Operating Company, Inc. (''Ribbon''). All rights reserved.
Copyright Copyright 2019 Ribbon Communications Operating Company, Inc. (''Ribbon'').. All rights reserved. This publication and the information contained herein is the property of the Ribbon and may not be copied, reproduced or distributed in any form or by any means without the prior written permission of Ribbon. Disclaimer and Restrictions The publication is for information purposes only and is subject to change without notice. This publication does not constitute a commitment on the part of Ribbon.
1. EdgeMarc 6000 Documentation Home . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1.1 About EdgeMarc 6000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1.2 Contact and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.1.3 License and Warranty . . . . . . . . .
EdgeMarc 6000 Documentation Home Getting Started Configuration Connecting Support License Hardware InstallationHardware Hardware Precautions Getting Started Table of Contents About EdgeMarc 6000 Contact and Support License and Warranty About EdgeMarc 6000 Introduction The newest addition to the Ribbon Intelligent Edge family is the EdgeMarc 6000.
2 FXO ports 4 LAN ports 2 Gb Ethernet ports for WAN 2 SFP WAN ports 4G/LTE Multi-tenant Management via Ribbon EdgeView Service Control Center Zero touch provisioning Remote monitoring Remote firmware upgrades Fault monitoring Troubleshooting Threshold alerts LAN/WAN MOS scores SIP ladder diagrams Ring buffers Contact and Support Customer Support To enter a trouble ticket, navigate to the Customer Support Portal to open a case. https://ribboncommunications.
on the same business day for next-day delivery (within the Continental US) if Ribbon Communications receives and acknowledges Purchaser’s notification by 1:00 PST. If Ribbon Communications, in its sole and independent determination, deems the Hardware to be allegedly defective or malfunctioning, then Ribbon Communications may refund the purchase price paid by the Purchaser. EdgeMarc Standard Limited Software Warranty Contact your local sales representative for warranty details.
EdgeMarc 6000 Hardware Specifications EdgeMarc 6000 Front Panel EdgeMarc 6000 Back Panel Ethernet Port LEDs MicroSD Card Features and Specifications Console Cable Pinouts EdgeMarc 6000 Hardware Installation EdgeMarc 6000 Appliance Shipping Contents Installation Prerequisites - Tools Required Installing EdgeMarc 6000 in a Rack Installing EdgeMarc 6000 on a Desktop, Shelf, or Tray Powering on the System Compliance and Regulatory Information EdgeMarc 6000 Class A Statements EdgeMarc 6000 FCC Notice EdgeMarc
Environmental requirements Operating Temperature: 32ºF to 104°F (0° to 40°C) Relative Humidity: 4% to 90%, non-condensing Certifications RoHS Compliant, WEEE Compliant Safety UL/cUL, LVD Emissions FCC part 15B, IC, CE, RCM, VCCI EdgeMarc 6000 Front Panel Figure 1: EdgeMarc 6000 Front Panel When lit, the Power LED indicates power is supplied to the system. The Status LED changes to indicate the current state of the system (Table 1).
Line (1-2) Phone (1-8) Off PSTN line is not in use. Solid Green PSTN line is in use. Off Phone is in the on-hook state. Solid Green Phone is in the off-hook state. EdgeMarc 6000 Back Panel Figure 2: EdgeMarc 6000 Back Panel When lit, the Power LED indicates power is applied to the system. The Status LED changes to indicate the current state of the system ( Table 1). Table 3: EdgeMarc 6000 Back Panel LEDs LED Indicator Description Power Off Power is not supplied to the device.
SFP Link (1-2) T1/E1 (1-2) Line (1-2) Phone (1-8) Solid Green Peer link is powered. Flashing LED Fiber traffic is active. Off T1/E1 port is not in use. Solid Green T1/E1 port is in use. Off PSTN line is not in use. Solid Green PSTN line is in use. Off Phone is in the on-hook state. Solid Green Phone is in the off-hook state.
Ethernet LAN ports 1-4 LAN 2x2 10/100/1000 Mbps RJ45 Ethernet ports for LAN network connectivity. LTE Micro SIM Slot 4G LTE Support Allows you to insert a 4G LTE micro SIM card thus allowing 4G network access. Micro SD Card Interface Storage Allows the EdgeMarc to save configurations and other files to an SD High Capacity (SDHC) Version 2.0 card. Maximum storage capacity is 32 GB per SD card, 4 GB per file.
Green Off There is no connection between the ends of the network cable. Check cable, replace cable. On-Flickering Green The adapter is sending and receiving network data. The frequency of the flashing varies with the amount of data being transferred. On-Solid Green The device is powered and there is a good link between the Ethernet port and the connected switch. Off The device is not powered, no cable connected, or the port speed is set to 10 Mbps.
MicroSD Card Commands mount = sdcard mount In FAT32 format if the microSD card (or SD card) was not properly unmounted, this command will result in the following syslog message: “Volume was not properly unmounted. Some data may be corrupt. Please run fsck.”Since EdgeMarc no longer supports dos fsck tool, this must be fixed either on an EdgeMarc with pre-15.3.0 VOS or on an appropriate Windows system.
3 TXD Pin 3 to Pin 2 RXD 2 4 GND Pin 4 to Pin 5 GND 5 5 GND Pin 5 to Pin 5 GND 5 6 RXD Pin 6 to Pin 3 TXD 3 7 NC _ _ _ 8 NC _ _ _ 3 C: Not Connected TXD: Transmit Data RXD: Receive Data GND: Ground EdgeMarc 6000 Hardware Installation Table of Contents EdgeMarc 6000 Appliance Shipping Contents Installation Prerequisites - Tools Required Installing EdgeMarc 6000 in a Rack Installing EdgeMarc 6000 on a Desktop, Shelf, or Tray Powering on the System Overview The EdgeMarc 6000 ap
Confidential and Proprietary. Copyright © 2019 Ribbon Communications Operating Company, Inc. (''Ribbon''). All rights reserved.
Installation Prerequisites - Tools Required In section: Tools Required Tools and Materials You will need the following tools and materials to install the EdgeMarc: Ethernet cables—To connect the LAN ports to LAN switches or to individual VoIP devices. Power Surge Protection EdgeMarc units are designed with a robust internal surge protection system. For more effective surge protection, it is recommended that the EdgeMarc be plugged into an external surge protector or UPS.
2. Make sure that the power and status LEDs on the front panel are solid green after the EdgeMarc powers on. 3. Proceed to Configuring Basic Network Settings. .
FCC Notice Class A Digital Device or Peripheral This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
attempt such connections appropriate authority, NOTICE: The Ringer Equivalence Number (REN) assigned to each relevant terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices does not exceed 5.
Deutsch [German]: Hiermit erklä rt Ribbon Communications, dass sich das Gerät EdgeMarc 6000 in Ü bereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet. Eesti [Estonian]: Käesolevaga kinnitab Ribbon Communications seadme EdgeMarc 6000 vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele.
Slovensky [Slovak]: Ribbon Communications týmto vyhlasuje, že EdgeMarc 6000 spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. Suomi [Finnish]: Ribbon Communications vakuuttaa täten että EdgeMarc 6000 tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
En utilisant votre équipement téléphonique, veuillez respecter les précautions de sécurité de base pour réduire les risques d’incendie, de choc électrique et de blessure aux personnes, dont les suivantes: N’utilisez pas ce produit proche de l’eau, par exemple près d’une baignoire, d’un évier, d’un lavabo ou d’une machine laver, dans un sous-sol humide ou près d’une piscine. Evitez d’utiliser un téléphone (autre qu’un sans fil) durant un orage. Il y a un risque de choc électrique distance depuis un éclair.
4 . Enter your initial username in the field provided: root 5 . Enter your initial password in the field provided: default 6 . Click OK. 7 . After you have logged in to the system for the first time with the default credentials, you are directed to the Change Password page (Figure 2). Figure 9: Change password page 8 . Enter your Current and New Passwords in the Change Password Page according to the new password instructions given in the page and then click Change Password.
Figure 10: EdgeMarc login screen Confidential and Proprietary. Copyright © 2019 Ribbon Communications Operating Company, Inc. (''Ribbon''). All rights reserved.
Figure 11: EdgeMarc Admin landing page Deploying the EdgeMark 6000 Session Border
Controller The EdgeMarc is deployed as a Session Border Controller on the network. For details about how to configure and deploy the EdgeMarc device in your network, refer to the EdgeMarc online help and the EdgeMarc VOS User Guide available in the Ribbon Communications Knowledgebase. Confidential and Proprietary. Copyright © 2019 Ribbon Communications Operating Company, Inc. (''Ribbon''). All rights reserved.
System Specification Model SKU EM-6000-8S-2X-P-L CPU EM-6000-8S-2X-P EM-6000-8S EM-6000-P EM-6000-L EM-6000 V - - - - - - - - - - CN9130 + 88F8215/2.0GHz/4 cores/Crypto System Memory Boot Flash Memory LAN DDR4 SO-DIMM (8GB) 8MB NOR/16GB eMMC 4x GbE WAN 2x GbE dual media (RJ45+ SPF) Console port RJ45 USB 3.0 port 1 Real Time Clock/RTC EEPROM DSP FXO FXS T1/E1 PRI LTE w/ uSIM M.