User manual
Q-Matrix 88 
User Manual
User Manual
Q-Tech Commercial Series Q-Matrix 88
7
1. Dip Switches
Dip switches set the Matrix system address. 
If the system is to be expanded, each Q 
Matrix unit must be defined as Master, Slave 
1, 2 or 3.
If you are expanding the system, only line 
inputs 1-8, MIC1 and 2 x Remote Paging 
Consoles of the Master Matrix are enabled. 
All Slave Matrix units connected to the Master 
will use the Master Matrix inputs. 
For the avoidance of doubt, if a Matrix unit is 
configured as a slave, the slave Matrix Inputs 
1 – 8, MIC1 and remote paging consoles 
inputs will be disabled. However, the optional 
wall plates (QTVCS and QT1WML) can be 
used to operate these additional zones.
Dip switch settings are as follows for 
configuring the Q Matrix 88 as a Master or 
Slave:
Rear Panel Layout
Quest Engineering have designed the Q Matrix 88 to provide maximum flexibility in terms of 
supporting several types of inputs which may be required in an installation.
The Q Matrix 88 features a bank of 8 line level inputs, a mixture of 4 phono inputs and four 
additional inputs which are configurable as either mic or line with phantom power available.
1 Dip Switches 9 LF Bass 17 Line Inputs
2 EVAC / Fire System Interface 10 Output 18 Paging Console Inputs
3 Tone Output 11 Gain 19 Paging MIC Gain
4 EMC Input  12 HF 20 MIC 1 Input
5 Extension Link 13 Enable/Disable Switch 21 MIC 1 Gain
6 Remote Source 14 Remote Source Gain 22 MIC 1 Bass
7 Remote Control Input 15 Fire Alarm 23 MIC 1 HF
8 Page 16 Line Gain
2
3 106 14
7
5
4
8
11
12
9
13
1
15 18 19 20 21 22
24
16
17
Master Matrix Extension Matrix 1
Extension Matrix 3
Extension Matrix 2