User manual
QTA 6000 Series 
User Manual
User Manual
Q-Tech Commercial Series
QTA 6060M/6120M/6250M 
8
23. Dipswitch “B” Positions 1-8
  Dipswitch 1 
  When set to the “100mV” position, the 
sensitivity of Input 6 is suitable for inputting 
Telephone Paging Signals. When set to the 
“300mV”position, the sensitivity of Input 6 is 
suitable for CD/DVD player outputs.
  Dipswitch 2-5
  When set to the “Line” position, input 
sensitivity is suitable for CD/DVD line level 
outputs. When set to the Mic” position, 
sensitivity is suitable for microphone inputs.
  Dipswitch 6
  When set the “Tel/Line” position, Input 1 
sensitivity is suitable for telephone paging 
and line level signals. When set to the “Mic” 
position, the sensitivity is set for microphone 
signals.
  Dipswitch 7
  When set to the “OFF” position, PHANTOM 
POWER is turned off on INPUTS 1-5. When 
set to the “ON” position, PHANTOM POWER 
(24VDC) is available on INPUTS 1-5 (mic 
position only).
  Dipswitch 8
  When set to the “Master” position, the VCA 
control port acts as an over all system remote 
volume control, adjusting all the input channels 
present on the master section mix bus up or 
down simultaneously. When set to the “Input 6” 
position, the VCA remote control port affects 
only the level of INPUT 6.
24. Zone 2 Level
  This rotary control will vary the signal level at 
the Zone 2 output terminals. Fully counter-
clockwise (0) is off; fully clockwise (21) is the 
maximum output level. The Zone 2 output gets 
its signal from INPUT 6, volume control.
25. VCA
  Remote location of the level control can be 
accomplished via the VCA control port. You 
can control the overall level (Master) or just 
Input 6.This selection is made via Dipswitch 
“B” position #8.Connect the two leads 
from the optional remote volume control to 
these terminals. This remote level control 
is POST Master and Input 5 Level Controls. 
Set the system’s maximum levels using the 
amplifier level controls and then use the 
remote VCA potentiometer as an attenuator 
from the maximum levels set. See the VCA 
setup section for instructions on wiring the 
potentiometer.
26. Remote Mute
  The Remote Mute feature is useful when 
the background system needs to be muted 
from a remote location. When shorting the 
Remote Mute terminals together, (G) to (M), the 
assigned channels will be muted.
  Note: Input 1 cannot be VOX or remote 
muted at anytime. Dipswitches 2-5 settings 
determine which inputs are to receive the Mute 
trigger. To trigger the mute it is common to 
use an external contact closure or switch on a 
microphone.
27. Zone 2 Output 600
  The 600 1.5V (Zone 2 Out) output is typically 
connected to a PABX MUSIC ON HOLD port, 
also known as MOH. The ZONE 2 output gets 
its signal from the INPUT 6, volume control.
28. Zone 2 Output 1 Watt 8
  The 8 Ohm 1W Zone 2 output can drive an 
external 8 Ohm speaker, and is taken Pre input 
6 gain control. Use the 1W 8 Ohm terminals for 
connection to an external speaker.
1 2 3 4 5 6 7 8
Input 6 Input 5 Input 4 Input 3 Input 2 Input 1 Phantom VCA
Sens
100mV Line Line Line Line Line off Master
300mV Mic Mic Mic Mic Mic on Input 6