Installation Guide
Apr-2019 Rev 12BI 7.2.3-8
Sources: APA - The Engineered Wood Association, TT-051C, 2011
Note: Lag pull-out (withdrawal) ultimate capacity = 350 lbs. in 1/2" plywood or 1/2" OSB.
IMPORTANT: To maintain waterproo ng it is important that the aluminum ashing (item 1) is properly placed under one full course above the mounting block with at least some of the
ashing extending up under the course above that as well. See instructions on back.
9.00
4.50
1.31
2.38
12.00
3.00
THIS EDGE TOWARDS ROOF RIDGE
.79
.04
1.46
3
4
CONDUIT CLAMP
NOT INCLUDED
1
2
AVAILABLE IN MILL, AND
BLACK FINISHES
ITEM
NO.
DESCRIPTION
QTY.
1
FLASHING, ROUNDED CORNERS, 9" X 12" X
.040", .500" HOLE, 5052, MILL
1
2
QBLOCK, CONDUIT, 5/16", CAST A360 AL, MILL
1
3
WASHER, SEALING, 1/4" ID X 1" OD, EPDM
BONDED SS
1
4
LAG SCREW, HEX HEAD, 1/4" x 2-1/2", 18-8SS
1
9
DO NOT SCALE DRAWING
SHEET 1 OF 1
AAP
SCALE: 1:3
WEIGHT:
REV
A
SIZE
TITLE:
DATE:
DRAWN BY:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
1/8
TWO PLACE DECIMAL
.19
THREE PLACE DECIMAL
.094
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED.
COPYRIGHT © 2019 QUICK MOUNT PV
5
4
3
2
1
UNLESS OTHERWISE SPECIFIED:
0.55
QMCC: CLASSIC CONDUIT
COMPOSITION MOUNT
4/3/2019
Lag pull-out (withdrawal) design values (lbs) in typical sheathing:
Lag Bolt Specifi cations
Specifi c Gravity 1/4" shaft per 1/2" thread depth 1/4" shaft per 1" thread depth
Plywood .45 72 144
OSB .45 72 144
Classic Comp Conduit Mount | QMCC
Elevated Water Seal Technology
®