QBase Universal Tile Mount Install Instructions
DEC-2019, Rev 15
BI 7.2.3-4
8
7
5
4
3
2
1
9
6
1
1
2
NOTES:
1
AVAILABLE IN MILL FINISH, AND BRONZE
ANODIZED FINISH
2
STAINLESS STEEL LAG SCREWS INCLUDED
WITH ANODIZED FINISH
ITEM
NO.
DESCRIPTION
QTY.
1
CAP SCREW, HEX HEAD, 5/16"-18 X 3/4" UNC-2A, GRADE 8,
MAGNI
1
2
QBASE, 1-1/4" ID, FOR 5/16" HARDWARE, A360 CAST AL
1
3
LAG SCREW, HEX HEAD, 5/16" X 3", ZINC
2
4
SUB-FLASHING, CONE, 9"X9"X.020"/.032", 3003 AL, MILL
1
5
FLASHING, CONE, 18"X18"X.032", 3003 AL, MILL
1
6
COLLAR, COUNTER FLASHING, 1-1/4" ID EPDM
1
7
POST, 1.25" OD X 6.5", 6063-T5/6063-T6, MILL
1
8
WASHER, SEALING, 5/16" ID X 1-1/4" OD, EPDM BONDED SS
1
9
CAP SCREW, HEX HEAD, 5/16"-18 X 1" UNC-2A, NYLON PATCH,
W/ CAPTIVE WASHER, 1"OD, 18-8 SS
1
13
DO NOT SCALE DRAWING
SHEET 1 OF 2
RAD
SCALE: 1:5
WEIGHT:
REV
A
SIZE
TITLE:
DATE:
DRAWN BY:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
1/8
TWO PLACE DECIMAL
.19
THREE PLACE DECIMAL
.094
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED.
COPYRIGHT © 2019 QUICK MOUNT PV
5
4
3
2
1
UNLESS OTHERWISE SPECIFIED:
2.27
QMUTM: QBASE UNIVERSAL TILE
MOUNT
8/9/2019
Source: AME Report 111316C, 7/5/2011
Please note:
1) The ultimate load is NOT the same as allowable load. Ultimate load is the load at the point of failure. Since point of failure is usually heavily dependent on the roof itself, allowable load
should be calculated by the responsible engineer using the appropriate factor of safety for that job.
2) Thread must be embedded in a rafter or other structural roof member.
3) See IBC for required edge distances.
QBase
®
Universal Tile Mount QMUTM
Ultimate Load Capacity
Test Setup
Average values based on failure tests results in Douglas Fir
Ultimate Load Capacity [lbf] Rafter moisture content (%) Rafter specic gravity Failure Mode
Pullout 3031 20.9 0.436
Lag Bolt Pulled Out
Shear Parallel to Rafter 803 13.8 0.438
Lag Bolt Pulled Out
Shear Perpendicular to Rafter 583 16.5 0.451
Plywood buckled/ Lag
Bolt Pulled Out
WARNING: Quick Mount PV products are NOT designed and should NOT be used to anchor fall protection equipment.