Specifications Sheet

Sources: American Wood Council, NDS 2005, Table 11.2 A, 11.3.2 A
Notes:
1) Thread must be embedded in a rafter or other structural roof member.
2) See NDS Table 11.5.1C for required edge distances.
Lag pull-out (withdrawal) capacities (lbs) in typical lumber:
Lag Bolt Specifi cations
Specifi c Gravity 5/16" shaft per 3" thread depth 5/16" shaft per 1" thread depth
Douglas Fir, Larch .50 798 266
Douglas Fir, South .46 705 235
Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) .46 705 235
Hem, Fir .43 636 212
Hem, Fir (North) .46 705 235
Southern Pine .55 921 307
Spruce, Pine, Fir .42 615 205
Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 798 266
E-Mount Lag | QMSE - LAG
Elevated Water Seal Technology
®
RACKING COMPONENTS
NOT INCLUDED
1
2
3
4
5
9.00
4.50
3.00
1.50
THIS EDGE TOWARDS ROOF RIDGE
1.29
.040
2.50
3.25 3.77
AVAILABLE IN MILL, AND
BLACK FINISHES
ITEM
NO.
DESCRIPTION
QTY./BOX
1
FLASHING, ROUNDED CORNERS, 9" X 12" X
.040", 5052, MILL
1
2
QBLOCK, CLASSIC, A360 CAST AL, MILL
1
3
PLUG, SEALING, 5/16" X 7/8", EPDM / 18-8 SS
1
4
LAG SCREW, HEX HEAD, 5/16" x 5-1/2", 18-8 SS
1
5
WASHER, FENDER, 5/16" ID X 1-1/4" OD, 18-8 SS
1
5
DO NOT SCALE DRAWING
SHEET 1 OF 1
RAD
SCALE: 1:3
WEIGHT:
REV
A
SIZE
TITLE:
DATE:
DRAWN BY:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
1/8
TWO PLACE DECIMAL
.19
THREE PLACE DECIMAL
.094
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED.
COPYRIGHT © 2016 QUICK MOUNT PV
5
4
3
2
1
UNLESS OTHERWISE SPECIFIED:
0.91
QMSE-LAG: QMPV E-MOUNT
WITH LAG BOLT
5/9/2017
May-2017 Rev 6BI 7.2.3-31

Summary of content (4 pages)