INSTALLATION INSTRUCTIONS
JOB SITE
SITE REQUIREMENTS
NatureTEK Select™ is a durable oor covering, not intended as structural material. NatureTEK Select requires a clean, dry,
secure suboor that meets building codes. The following requirements are not intended to supersede federal, state or local
building codes, but as with many other interior nish products, may require modifying existing structural components for
successful installation. Owner assumes responsibilities for compliance with all building codes. NatureTEK Select ooring is
suitable for use in climate controlled (35-65% RH and 60-85° F) indoor installations only and should not be installed in rooms
with oor drains or sump pumps. NatureTEK Select oor can be installed above, on or below grade. A moisture test is strongly
recommended to determine if high moisture exists in the suboor. When using a calcium chloride moisture test for concrete
suboors (ASTM F1869), values must be ≤ 5 lbs/1000ft²/24-hr or <80% RH with an in situ probe (ASTM F2170). Moisture
readings of wood suboors must be ≤ 12%. Acceptable job site conditions, including relative humidity and suboor moisture
conditions, must be maintained throughout the lifetime of the ooring. NatureTEK Select ooring is installed as a oating oor
and requires the use of T-moldings in doorways less than 32-inches (0.81m) or if the installation changes directions through
the doorway (regardless of doorway size) and in rooms 50 feet (15.24m) or larger in length or width. Floor movement must not
be constrained by glue, nails, screws, hardware or other xed obstructions. This product must be installed in accordance with
these installation instructions.
10' (3 m)
10 pi
> 5" (130 mm)
>5 po
6 mil (0.15 mm) virgin PE vapor barrier
Barrera de vapor de 6 mil (0,15 mm) de polietileno virgen
ground
suelo
> 8" (200 mm)
>8 po