Installation & Assembly

Quick
Step
®
NatureTEK Plus
Installation Instructions
0328_August/2019
Page 1 of 4
INSTALLATION INSTRUCTIONS
JOB SITE
SITE REQUIREMENTS
NatureTEK Plus™ is a durable oor covering, not intended as structural material. NatureTEK Plus requires a clean, dry, secure
suboor that meets building codes. The following requirements are not intended to supersede federal, state or local building
codes, but as with many other interior nish products, may require modifying existing structural components for successful
installation. Owner assumes responsibility for compliance with all building codes. NatureTEK Plus ooring is suitable for use
in climate controlled (35-65% RH and 60-85° F) indoor installations only and should not be installed in rooms with oor drains
or sump pumps. NatureTEK Plus oor can be installed above, on or below grade. A moisture test is strongly recommended to
determine if high moisture exists in the suboor. When using a calcium chloride moisture test for concrete suboors (ASTM
F1869), values must be ≤ 5 lbs/1000ft²/24-hr or <80% RH with an in situ probe (ASTM F2170). Moisture readings of wood
suboors must be ≤ 12%. Acceptable job site conditions, including relative humidity and suboor moisture conditions, must be
maintained throughout the lifetime of the ooring. NatureTEK Plus ooring is installed as a oating oor and requires the use of
T-moldings in doorways less than 32-inches (0.81m) or if the installation changes directions through the doorway (regardless
of doorway size) and in rooms 50 feet (15.24m) or larger in length or width. Floor movement must not be constrained by
glue, nails, screws, hardware or other xed obstructions. This product must be installed in accordance with these installation
instructions.
10' (3 m)
10 pi
> 5" (130 mm)
>5 po
6 mil (0.15 mm) virgin PE vapor barrier
Barrera de vapor de 6 mil (0,15 mm) de polietileno virgen
ground
suelo
> 8" (200 mm)
>8 po

Summary of content (4 pages)