User manual
                              Transponder Access Control Kit 
Version: 1.0                    3 
(2) Key “1”: register cards in continuous way 
Press “1” → continuously presenting the unregistered card → press “ENT” to confirm → press 
“9” to exit 
  The system will give a number to each card. The original password is “888888”. Such 
password can only be used for Card and Password Mode. 
  If there is no card in the system, the card number will start from “0001” and increase 
gradually. The largest number cannot exceed “6399”.   
  If the registered already exist, the number will increase from the number of previous 
registered cards (including the deleted cards). 
  If add successfully, the buzzer will make two short sound “di di”, otherwise, make a 
long sound “di”. 
  To be able to delete cards without presenting it is strongly recommended to write this 
number on the card or make a similar notice. 
(3) Key “2”: register a single card (allow registering card continuously) 
Press  “2”  →  present the  card  →  input  the  4-digit  user  number  →  press  “ENT”  →present 
another card →input the 4-digit user number → press ‘ENT” (…..continuously register cards) 
→ press “ENT” →press “9” to exit 
  The system will give a default password  “888888” to each card. This password can 
only be used in the Card and Password Mode. 
  If the card has already existed, the buzzer will make a long sound “di”. Then you can 
present another card. If the inputted number has already existed, the buzzer will make 
a long sound “di”. Then you can input another number. 
(4) Key “3”: delete the registered card 
Delete  card  by  presenting:  Press  3,  0  →  present  the  card  →present  another  card 
(Continuously present the card that need to be deleted) → press “ENT” → press “9” to exit 
Delete by user number: Press 3, 1 → input the user number → press “ENT” → input another 
one→ press “ENT” (continuously delete many user numbers) → press “ENT”   
→ press “9” to exit 
Delete all cards: Press 3, 2 → input “9999” → press “ENT” →press “9” to exit 
(5) Key “4”: Door open mode setting 
Card or password: Press 4, 0      → press “ENT” →press “9” to exit (that is the factory default 
mode) 
Card and password: Press 4, 1 → press “ENT” → press “9” to exit 
Password only : Press 4, 2 → press “ENT” → press “9” to exit 