Installation Guide

8
8. Push the door until the soft-closer “grabs” the door and softly closes it. Adjust the
position of the actuator, if necessary, to soft-close the door.
Note: It is also critical that the actuator is positioned in such a way that, when opening the door, the soft-close
mechanism returns and stops in the “loaded” position, ready to engage with the actuator when the door is to
be soft-closed again.
7. Reinstall the door (figure 5f). With the soft-close mechanism in the “loaded” position,
move the door until the actuator meets the soft-closure. Verify that the actuator is
in the correct position on the door so that the actuator fully engages the soft-close
mechanism (figure 5e).
Loosen the rail screws near the soft-close
mechanisms to make it easier to reinstall
the door.
Install the door on the rail and re-tighten
the screws.
Figure 5e
Figure 5f