Technical Specifications
Your Underlayment Specialists!
(888)379-9695 • Fax (402)379-9737 • www.mpglobalproducts.com
2500 Old Hadar Road • P.O. Box 2283 • Norfolk, NE 68702-2283
www.quietwarmth.com
For Use Under Laminate, Wood and Tile Floors
For Use Under Laminate, Wood and Tile Floors
1. Dampen, but do not saturate, the QuietWarmth
®
with a sponge or mist sprayer prior to thin-set application.
2. Use a square or “U” notch trowel (Use plastic trowel if available) that is sized appropriately for the size of tile and required
to achieve 95% coverage. (Minimum 1/4” x 3/8” x 1/4”).
3. Use Latex Portland cement mortar that conforms to test requirements found in ANSI A118.4 or 118.11.
4. Key the thin-set into the QuietWarmth
®
with the at side of the trowel and then comb it with the notched side in the same
direction as the QuietWarmth
®
heating elements, taking care not to damage the heating element.
5. Press the tile into the thin-set using a front to back motion perpendicular to the spread of the thin-set for maximum transfer
of the thin-set onto the tile.
6. Mortar average coverage per tile shall comply with ANSI A108.5.3.3.3, which requires:
a) The back buttering of each tile b) At least 95% thinset coverage on each tile.
7. Minimum grout joint width is 3/16”.
8.
9. Use epoxy grout as per manufacturers instructions.
QuietWarmth is for 120V Installations ONLY! See section 1-E.
Serial number_____________
Pad Size_________________
Volts ____________________
Factory Resistance____Ohms
_______
(Ohms)
_______
(Ohms)
_______
(Ohms)
Serial number_____________
Pad Size_________________
Volts ____________________
Factory Resistance____Ohms
_______
(Ohms)
_______
(Ohms)
_______
(Ohms)
Serial number_____________
Pad Size_________________
Volts ____________________
Factory Resistance____Ohms
_______
(Ohms)
_______
(Ohms)
_______
(Ohms)
Serial number_____________
Pad Size_________________
Volts ____________________
Factory Resistance____Ohms
_______
(Ohms)
_______
(Ohms)
_______
(Ohms)
QuietWarmth is covered by a 10-Year Limited Warranty. See our complete warranty
at , or call us at to request a copy
US Patent #US 6,563,094 B2
• Made with Thermosoft® FiberThermics® Heating Elements
• Operated by a Digital or Programmable thermostats
Cautions:
THIS EQUIPMENT SHALL BE INSTALLED ONLY BY QUALIFIED PERSONNEL WHO ARE FAMILIAR WITH THE
CONSTRUCTION AND OPERATION OF THE APPARATUS AND THE RISKS INVOLVED.
THE INSTALLATION OF THIS HEATING PRODUCT SHALL BE IN ACCORDANCE WITH THE MANUFACTURER’S
INSTRUCTIONS AND LOCAL AND NATIONAL CODES.
IN CANADA,THE INSTALLATION SHALL BE MADE ACCORDING TO THE PROVISIONS OF SECTION 62 OF THE
CANADIAN ELECTRICAL CODE, PART 1.
WARNING - AS DESCRIBED IN THESE INSTRUCTIONS, LEAD WIRES ARE NOT TO BE ROUTED OVER PADS OR
COME INTO CONTACT WITH THE HEATING ELEMENTS AS DAMAGE TO SUPPLY CONDUCTOR INSULATION
MAY OCCUR IF CONDUCTORS ARE ROUTED TO CONTACT HEATING ELEMENTS. REFER TO INSTALLATION
INSTRUCTIONS FOR RECOMMENDED MEANS OF ROUTING SUPPLY CONDUCTORS.
THE TYPE AND THICKNESS OF FLOOR COVERING MATERIALS USED WITH THIS PRODUCT MUST NOT
EXCEED A THERMAL INSULATION “R” VALUE OF 2.0.
CAUTION: USE COPPER ONLY AS SUPPLY CONDUCTORS. THERE ARE NO SPECIAL CRIMPING TOOLS
REQUIRED FOR THIS PRODUCT.
V-5 5/2014