Installation Instructions

P
ART 2 - JOB-SITE PREPARATION
PREPARATION
Before work can proceed, all plumbing and electrical wiring that will
not be accessible after installation of the heating system must be com-
pleted. This may require coordinating with the electrical and/or plumb-
ing contractor(s).
Make sure that insulation has been installed in areas that will be inac-
cessible after installation of the heating system. This may require coor-
dinating with the insulation contractor.
Before installing the Calorique Warm Floors System, all of the follow-
ing must be available at the job-site.
COMPONENTS
Name Part Number Description
•Heating Panels table pg 4 The number and type of heating
panels needed must have been
calculated before-hand as out-
lined in Part 1-Design Criteria.
Enough panels must be on hand
to account for any errors in cut-
ting, job-site damage, etc.
•Electrical Connector FC-1001 Solderless Tyco/AMP Termi-foil
electrical crimp connector.
•Electrical Insulator FB-1001 Clear plastic snap-type insulator.
Thermostat or Control UL Listed thermostat or other
appropriate control rated for at
least 25% greater capacity than
the installed heating load. Low
voltage units may be used in
combination with appropriate
relay.
Thermal Insulation The insulation must be of the
non-flammable type specified
during calculations done per Part
1. See page 3 for details.
Non-Heating Leads Branch circuit supply conductors
shall be no larger than #12 AWG
or smaller than #14 AWG, with
overcurrent protection of 20
amperes. Type UF single conduc-
tor or equivalent.
JOB-SITE PREPARATION
NOTE
Those components marked with the symbol are supplied by your
Calorique distributor.
5

Make sure
that the job-
site is neat
and clean before
working with the
Calorique radiant
heating panel sets.
Nails, screws and
other sharp debris
can damage the pan-
els. Any panels which
become torn or oth-
erwise damaged must
be discarded.
If insulation is being
installed by another
contractor, this infor-
mation must be made
available and compli-
ance ensured.
Type NM and NMC
non-metalic sheathed
cable is not suitable
for installing this
product.
Caution: Use copper
only as supply con-
ductor.