Installation Guide

1-888-QUIETCOOL 8
5. Tie the black wire from the power source to the remaining black wire from the thermostat.
6. Using the ground screw in the thermostat, ground your power source and the green wire from
the fan.
7. Mount the thermostat to one of the joists near the attic fan.
Ground the fan and power to the thermostat
using the green ground screw
Specialty Series Fan
Power Source
14-2 Wire
2 Wire Romex
Thermostat
Low Speed
High Speed
Figure 3.1A
Ground the fan and power to the thermostat
using the green ground screw
Specialty Series Fan
Power Source
14-2 Wire
2 Wire Romex
60°
Thermostat
Low Speed
High Speed
Figure 3.1B
3.2 REMOTE THERMOSTAT WIRING
1. For this installation, you will need a 2 wire Romex, junction box, and a thermostat.
2. Open up the thermostat that is connected to the fan. Remove the power cord. Remove the bracket
mounting the thermostat to the ex tubing and remove the thermostat. Mount a junction box to
the ex tubing with the included bracket and mount the junction box. Bring your 2 wire romex from
the power source into the junction box.
3. Mount the thermostat in the best location for thermostat readings. Run a 2 wire Romex from the
junction box to the thermostat. Tape the white wire on each side of the 2 wire Romex to indicate that
it is a switch leg.