Owner's Guide
1-888-QUIETCOOL
8
4. In the junction box, with a wire nut, tie the white common wires together. Using the green ground
screw, ground the green wire from the fan and the 2 wire Romex from the thermostat, to the junction
box.
5. High Speed: Tie the black wire from the fan to the taped white wire from the thermostat (see Figure
3.2A)
Low Speed: Tie the red wire from the fan to the taped white wire from the thermostat (see Figure
3.2B)
6. Tie the black wire from the power source to the black wire from the thermostat. Replace the cover
on the junction box.
7. In the themostat, tie the black wire to one of the black wires from the thermostat. Tie the taped
wire to the other black wire from the thermostat. Using the ground screw in the thermostat, ground
the ground wire from the 2 wire Romex.
8. Tie the two remaining black wires together. Then, tie the remaining copper wires together.
Ground the fan to the junction box
using the green ground screw
Specialty Series Fan
Junction
Box
Power Source
14-2 Wire
14-2 Wire
14-2 Wire
60°
Thermostat
FAN ON
TEMPERATURE
90°
120°
®
ADJUSTABLE
TEMPERATURE THERMOSTAT
CAUTION
Automatically started device - to reduce the
risk of injury disconnect from power supply
before servicing. For residential use only. See
instructions for wiring diagram.
60°
ADVANCED ATTIC GABLE FANS
®
Figure 3.2A
Ground the fan to the junction box
using the green ground screw
Specialty Series Fan
Junction
Box
Power Source
14-2 Wire
14-2 Wire
14-2 Wire
60°
Thermostat
FAN ON
TEMPERATURE
90°
120°
®
ADJUSTABLE
TEMPERATURE THERMOSTAT
CAUTION
Automatically started device - to reduce the
risk of injury disconnect from power supply
before servicing. For residential use only. See
instructions for wiring diagram.
60°
ADVANCED ATTIC GABLE FANS
®
Figure 3.2B