Instructions / Assembly
QUIETCOOLSYSTEMS.COM
4
2. INSTALLATION
2-1 Installing the Hub
IMPORTANT: If you are installing the Hub onto an existing QuietCool fan, be sure
to shut off the power before attempting installation. If you are installing the Hub
onto a new fan, perform all installation steps before plugging in the fan.
1. Open up the thermostat on your attic fan. Unwire the power cord and remove the plastic
connector. Unwire the motor wires and remove the metal connector and flex from the
thermostat.
2. Attach the metal connector and flex to one of the knockouts on the IT-AF-SMT hub. Attach the
plastic power cord bushing in another knockout on the hub.
2-2 Wiring the Hub
NOTE: Wiring Diagrams are for examples only and wiring should be done
by an experienced electrician. 12 or 14-gauge romex is common. Check your
local building code before choosing the wire type.
NOTE: Ensure the power is disconnected before performing any wiring
connections.
NOTE: The wiring diagrams and instructions are shown using the power cord
included with your QuietCool. The installation can also be performed with
2-wire romex and hard wired.
One Speed Wiring (see Figure A)
1. Using a wire nut, connect the black wire from the power cord to the black wire from the
Hub.
2. Connect the white wire from the power cord and the white wire on the fan to the white
wire from the Hub.
3. Connect the black wire from the fan to the blue wire on the Hub
4. Cap the red wire on the Hub.
5. Cap the yellow wire from the Hub.
6. Ground the green wire from the fan and the green wire from the power cord to the
ground screw in the Hub.
TOOLS YOU WILL NEED
- Phillips screwdriver - Power-drill - Philips bit