ADVANCED WHOLE HOUSE FANS ® THE NATURAL CHOICE FOR ENERGY SAVINGS! OWNER’S GUIDE ENERGY SAVER CLASSIC LINE S E E // H E A R // F E E L THE QUIETCOOL DIFFERENCE 1 QUIETCOOLSYSTEMS.
GENERAL SAFETY INSTRUCTIONS 1. 2. 3. 4. 5. Read Instructions - All safety and operation instructions must be read. Retain Instructions - The safety and operating instructions should be kept for future reference. Heed Warnings - All warnings should be followed. Follow Instructions - All installing and operating instructions should be followed. Water - The QuietCool system should not be used near water.
1. SYSTEM OVERVIEW 1.1 INTRODUCTION Congratulations on the purchase of your new QuietCool system! The QuietCool whole house fans dominate the market in energy efficiency and quietness. Whole house fans operate by pulling the cool air from outside your home, through the home, into your attic, and out your attic vents. This accomplishes a cooling effect that can save you up to 90% off your A/C related energy costs depending on where you live.
1.3 Benefits 1.4 System Venting Requirements VERY IMPORTANT! - 1 SQUARE FOOT OF NET FREE VENTING PER 750 CFM REQUIRED VENTILATION: 1 SQ. FT FOR EACH 750 CFM Vent Type 2 Model Type Average Size Venting Sq. Ft. Gable vent 12” x 19.5” 1.20 Dormer Vent 14” x 8” 0.70 Eave Vent Various Various Ridge Vent Various Various Soffit Vent Various Various QUIETCOOLSYSTEMS.
2. INSTALLATION 2.1 Installing QuietCool NOTE: Be sure to plug in your fan before attempting to install to ensure that the fan is operational. If the fan is not operational, call the company that you purchased the fan from and request an exchange. Installing the QuietCool system is very easy. Simply follow the steps given below: 1. Determine from down below in which areas you would like to install your QuietCool fans. Go up into the attic to mark the exact location for each fan.
3. From below, place the cut-out template on the ceiling at each location, making sure that you have at least 2 inches of clearance all around it. While holding the template in place, mark its outline with a pencil. NOTE: Repeat these steps at each location. 4. Using a drywall saw or similar device, cut out the hole in the ceiling. NOTE: Repeat these steps at each location. 5. Open and unpack each QuietCool fan.
6. Hang the motor head from the rafters by fastening the metal strapping that is attached to the motor head to the rafters with the wood screws. Make sure the power box on the moter head is at the very top. Secure duct to damper box using three black sharp screws. Make sure the duct has a gentle 90 degree bend to help reduce noise level. NOTE: Once all of the QuietCool fans are hung, it’s time to go below and install the ceiling box and ceiling grill at each intake location. 7.
VERY IMPORTANT: Make sure the fan blade spins freely. This is very important to system operation NOTE: Local building codes and standards must be adhered to in the installation of this unit. AVOID BACK DRAFTS: Care should be taken to avoid back drafting combustion appliances that are installed in the conditioned space. It is strongly recommended that combustion appliances NOT be installed in such a manner that they use room air for combustion.
3.1 Single Speed Wiring (for ES-1500/ES-2250/ES-3100) 1. For this installation, you will need (2) 2 wire Romex, and an 8 Hour Timer. Using the included wire nuts, tie the black wire from the first 2 wire Romex from the power source to the black wire on the timer. (see Figure 3.1A) 2. Using a wire nut, tie the black wire on the 2 wire Romex from the fan to the red wire on the timer. 3. Using a wire nut, tie the bare copper wires together with the green ground wire on the timer. Figure 3.
6. Feed the 2 wire Romex through the handy box. Using the included wire nuts, tie the black wires together. Tie the white neutral wires together. Tie your bare copper wire and green ground wires together. 7. Carefully reinstall the handy box cover. Figure 3.1B Tie All Ground & Bare Copper Wires Together Whole House Fan All Black Wires Together 14-2 Wire Switch All White Common Wires Together 3.2 Two Speed Wiring (for ES-4700) 1.
Figure 3.2A Power Source Whole House Fans 8 HOUR High 4 HOUR Taped White Low Speed Tie All Ground & Bare Copper Wires Together Black High Speed Black Wires Together 14-2 Wire Tie White Common Wires Together 14-2 Wire 14-2 Wire 2 HOUR OFF 1 HOUR HOLD Low Red Switch Leg Figure 3.
8. Feed the 2 wire Romex from your switch into the handy box. Tape the white wire on this end of the Romex. Tie the blue & black wire together for high speed. Tie the red and taped white wire together for low speed. 9. Feed the 2 wire Romex from your timer into the handy box. Feed the 2 wire Romex from your power source into the handy box. 10. Tie the three remaining black wires together. Tie the three remaining white wires together. Tie the three bare copper wires and the two green ground wires together.
9. Feed the 2 wire Romex into the handy box. Using the included wire nuts, tie the black wires together for high speed. Tie the remaining white neutral wires together. Tie your bare copper wires and green ground wires together. Carefully reinstall the handy box cover. Figure 3.
4. SYSTEM OPERATING INSTRUCTIONS 4.1 When to Run the QuietCool Whole House Fans Anytime it is cooler outside than the inside of your home, the system will work effectively. In the summer this normally happens in the late afternoon to early evening, through to the next morning. We recommend running your fan through the evening. If you have a multi-speed fan, you will get the best cooling effect when you turn the fan on low after desired cooling occurs and let it run throughout the night. 4.
WHOLE HOUSE FANS LIMITED WARRANTY 10 YEAR LIMITED WARRANTY QC ES LINE (Energy Saver) WHOLE HOUSE FANS QC Manufacturing Inc. extends this warranty to the original purchaser of the following QuietCool Classic Line Models ----QC ES-1500, QC ES-2250, QC ES-3100, QC ES-4700 and QC ES-6400 ---- installed and used in a residence under normal conditions within the United States: A. Ten year coverage applies to the QuietCool motor fan assembly.
QuietCool is Proudly Designed and Built in California ADVANCED WHOLE HOUSE FANS 1-888-QUIETCOOL 43352 Business Park Drive, Temecula, CA 92590 ® // PH 951.325.6340 // QUIETCOOLSYSTEMS.