Instructions / Assembly
1-888-QUIETCOOL 4
INCLUDED
- QuietCool RM Whole House Fan
- RM Hardware Kit
- Cut-out Template
- (2) Window Locks
- PL Accessory Kit (if purchased)
- DB Accessory Kit (if purchased)
- DG1/2 Accessory Kit (if purchased)
RM HARDWARE
KIT CONTENTS
A. (5) All-Purpose Screws
4 for Hub, 1 extra
1.3 SYSTEM VENTING REQUIREMENTS
VERY IMPORTANT: 1 SQUARE FOOT OF
NET FREE VENT AREA PER 750 CFM
RECOMMENDED: 2 TO 4 SQUARE FEET
OF INLET VENTS PER FAN
Venting plays a very signicant role in the
performance of QuietCool fans. QuietCool
recommends a minimum of 1 SQ. FT. of
venting for every 750 CFM in the Quiet-
Cool system. If an attic has at least 1:750
attic venting, the QuietCool system will
operate efciently and effectively. If an
attic has less than 1:750 attic venting, the
system may not operate as efciently, or
effectively, as it could with 1:750 attic vent-
ing. But don’t worry, the system will still
operate if there is not enough venting.
Insufcient venting is a very simple prob-
lem to x. Roong contractors can add
extra venting to most homes simply and
easily. The most common types of venting
is shown in the chart below.
!!
!!
A.
PL HARDWARE
KIT CONTENTS
D. (9) Hex Head Self Drilling
Screws with Rubber Bonded
Washers
(8 for fan to plenum, 1 extra)
D.
DB HARDWARE
KIT CONTENTS
A. (9) All-Purpose Screws
4 for damper box, 5 extra
B. (6) Pan Head Screws
4 for duct strap, 2 extra
C. Duct Strap
B.
A.
Vent Type Model Type Average Size Venting Sq. Ft.
Gable vent 12” x 19.5” 1.20
Dormer Vent 14” x 8” 0.70
Ridge Vent 4’ - 12’ 0.125 per ft
Soft Vent
16” x 4”
16” x 6”
16” x 8”
0.19
0.29
0.39
O’Hagin Vent
Low/Medium Prole
Tapered Low Prole
Low Prole Flat
High Prole
0.5
0.6
0.68
0.68
*Note: This table is only a guideline and is not a guarantee of venting capacity.
TOOLS YOU WILL NEED
+ Cordless Drill with Nut Driver
+ Roong Nails
+ Reciprocating Saw
+ Measuring Tape
+ Weatherproof Roong Grade Sealant
+ Roong Knife
+ Peel-and-stick or similar roong material
+ Weatherproof roong paper
+ Shingle material (for shingle roofs)
+ Aluminum Secondary Flashing Material (for tile roof)
+ Angle Grinder (for tile roof)
+ Ladder Marker or Carpenter Pencil