Technical information

www.quietside.com
30
MH052FNCA Multi Zone Heat Pump
Neo Forte High Wall Indoor Unit
Matching Outdoor unit: MH080FXCA4A
Power
Power Voltage :
208/230V 1 Ph 60 Hz
Control Voltage :
DC Fuzzy Logic
Main Breaker Size :
No Dedicated Circuit Indoor
Unit is Powered by the
Outdoor Unit
Line Sizes :
“Liquid” (expanded gas) line
1/4”
Suction
1/2
ALL LINES MUST BE INSULATED SEPARATELY
Interconnect Length
Maximum Combined Length
Maximum / Minimum Individual Length
Vertical lift
(Note evaporator can be above or below condenser)
Charging
Unit is charged for
Nitrogen Holding Charge Only
Additional Charge of R410A
See Outdoor Unit
Interconnecting Wiring
Gauge
14 AWG Power, 1(L), 2(N) & 16 AWG Shielded Communication, F1, F2
Number of Interconnecting Wires
3x14 AWG Power & 2x16 AWG Control = 5 Total