AR24HSFSHWKNCV Heat Pump Mini Split
Indoor Unit : AR24HSFSHWKNCV Outdoor Unit : AR24HSFSHWKXCV
Power
Power Voltage :
208/230V 1 Ph 60 Hz
Control Voltage :
DDC Fuzzy Logic
Main Breaker Size :
30 A
Line Sizes :
“Liquid” (expanded gas) line
1/4
Suction
5/8”
BOTH LINES MUST BE INSULATED SEPARATELY
Interconnect Length
Maximum / Minimum Length
Vertical lift
(Note condenser can be above or below evaporator)
Charging
Unit is charged for
25 ft (Factory Charge 81.1oz R410A)
Additional Charge of R410A
0.43oz/ft over 25ft
Charge for Line Run lengths
Length
25
35
45
55
65
75
85
95
98
Added Charge (oz)
0
4.3
8.6
12.9
17.2
21.5
25.8
30.1
31.39
Interconnecting Wiring
Gauge
14 AWG Power &16 AWG Shielded Communication
Number of Interconnecting Wires
3x14 AWG Power & 2x16 AWG Control = 5 Total