ENGLISH QK-H300 QK-H400 HYDRO HYDRAULIC SWING GATE OPENER USER INSTALLATION MANUAL
QK-H300 QK-H400 QK-H300BC QK-H400BC 230VAC 50 Hz 1,6 300 TECHNICAL FEATURES POWER SUPPLY CURRENT ABSORBED (A) POWER ABSORBED (W) INCORPORATED CAPACITOR (mF) 10 PROTECTION LEVEL (IP) OPENING TIME (sec) TRAVEL (mm) MAX.
PRE-INSTALLATION CONTROL Before installing the automation, you must check that the gate’s shutter: - The leaf turn freely in the hinges and without sticking in the ground It does not swing during its movement; is kept in axis by the special hinges; the leaves have the proper stoppages when opening and closing. Borinato F.lli Snc is liable only for products it manufactures and commercializes. Once automated, the gate becomes a machine and is therefore subjected to the rules of the “ Machinery Directive”.
INSTALLATION MATERIALS Fig.
INSTALLATION 1- Arrange the electric cables installation and connection according to the below Fig.2 Fig 2 2- Unloose and remove the two screws # 11 (fig 1) that fastens the tie rod cover to the cylinder.
Fig 3 QK-H300 QK-H400 α = 90° α = 95°° B (mm) B (mm) A (mm) A (mm) min max min max 100 120 170 120 130 170 110 120 170 130 130 170 140 120 150 L MAX (mm) 1010 α = 90° α = 95° B (mm) B (mm) A (mm) A (mm) min max min max 110 120 250 120 120 220 120 120 250 130 120 220 150 120 250 160 120 210 200 120 190 210 120 160 210 120 190 220 120 160 220 120 180 230 120 130 230 120 160 240 120 120 Table 1 4- Temporary fix the actuator to the wall and to the leaf (tack weld) and turn the leaf gate from the close pos
The opening and closing forces transmitted to the gate by the cylinder are regulated by adjusting two by pass valves. The blue valve adjusts the opening pressure. The red valve the closing pressure. Fig. 4 + increase the actuator thrust - decrease the actuator thrust 8- After installation take away the breather screw from the actuator Fig. 5 Fig.
10 – To release the opening and operate the leaves manually insert the release key as shown in the Fig. 6 Fig.
Fig 7 Risk Areas on Hinged Gates (figure 7) LEGEND OF MECHANICAL RISKS CAUSED BY MOVEMENT In accordance with the Regulation on Machinery, the following definitions are applicable: − “Danger Zones:” any area inside and/or near a machine where the presence of a person is a risk to his/her health and safety. − “Exposed Person:” any person located entirely or partially in a danger zone. Impact B E C A. A F D B. Crushing D. Conveyance C. Insulation E. Cutting F.
DECLARATION OF COMPLIANCE (by the installer) The undersigned: Address: in charge of the set-up, declares that the product: Gate type: Location: are in compliance with the essential safety requirements of the regulations: Regulation 89/392CE on Machinery and its subsequent amendments; EMC Regulation 89/336/CE (Legislative Decree 615/96); BT Regulation 73/23/CE e 93/68/CE (Legislative Decree 626/96); CE Machinery Directive 98/37 and directive 93/68/CE-72/23/CE-92/31/CE; and also declares that t
DECLARATION OF COMPLIANCE (in accordance with the European Regulation UE89/392 Appendix IIA) Manufacturer: Borinato F.
Borinato F.lli Snc Via Seccalegno 19 36040 Sossano (Vi) Italy Tel + 39 0444 785513 Fax +39 0444 782371 INFO@QUIKO.BIZ www.quiko.