Product Manual
Single Stage Series Quincy Compressor
1312101105, September 2013 9 3501 Wismann Lane, Quincy IL - 62305-3116
1. Useadditionalhoseinstead
of extra extension cord or use
heavier gauge extension cord.
2. Repair electrical connections.
3. Check with voltmeter.
4. Replace with correctly sized
motor.
5. Replace motor.
6. Changepowercord&voltage
of motor to match voltage of
power source.
3. Fuses blow or circuit
breakers trip.
2. Motor hums or runs
slowly when first
turned on.
1. Light duty extension cord be-
ing used.
2. Loose electrical connection.
3. Low voltage.
4. Motor sized incorrectly.
5. Defective motor.
6. Motorvoltagedoesnotmatch
voltage of power source.
1. Loose electrical connection.
2. Too many lights or appliances
being operated on the same
circuit as the compressor (cir-
cuit overloaded).
3. Defective check valve or un-
loader.
4. Low voltage.
5. Motor sized incorrectly.
6. Incorrectsizefuseorcircuit
breaker.
7. Defective motor.
8. Motor voltage does not match
voltage of power source.
1. Repair electrical connections.
2. Try another circuit or remove
other appliances from circuit
being used.
3. Replace check valve or un-
loader.
4. Check with voltmeter.
5. Replace with correctly sized
motor.
6. Checkforpropersizefuse.
7. Replace motor.
8. Change power cord & voltage
of motor to match voltage of
power source.
PROBLEM CAUSES CORRECTION
1. Plugpowercordin.
2. Switchto“AUTO”.
3. TurnOFF/AUTOswitchto
the“OFF”position.Pushthe
motor thermal over load (red)
button firmly until a click
isheard.TurnAUTO/OFF
switchto“AUTO”.
4. Replace fuse or reset circuit
breaker.
5. Replace or repair pressure
switch.
6. Replaceorrepairmotor.
7. Add lubricant (refer to Lubri-
cation).
8. Adjust belt (refer to Belt
Alignment & Adjustment).
9. Change power cord & volt-
age of motor to match power
source.
1. Powercordnotpluggedin.
2. OFF/AUTOswitchin“OFF”
position.
3. Motor overload relay tripped.
4. Fuse blown &/or circuit
breaker is tripped.
5. Defective pressure switch.
6. Defectivemotor.
7. Lack of lubricant in compres-
sor (can cause serious damage
to compressor).
8. Belt too tight or too loose.
9. Motor voltage does not match
voltage of power source.
1. Compressor won’t
operate.
TROUBLESHOOTING
Read and understand all the safety precautions listed in the front of this manual and follow all procedures