Product Manual

Single Stage Series Quincy Compressor
1312101105, September 2013 2 3501 Wismann Lane, Quincy IL - 62305-3116
This instruction manual, and any instructions
supplied by manufacturers of supporting equipment,
should be read and understood prior to assembling,
starting or disassembling the compressor. Be thor-
oughly familiar with the controls and proper use of
this equipment. If there are any questions, please
call your local Quincy distributor.
Safety Precautions
•Relievethesystemofallpressurebeforeservic
ing any part of the unit.
•Allowampletimeforthecompressortocoolbe-
fore performing service procedures. Some surface
temperatures exceed 350°F when the compressor
is operating.
•Allinstallation,maintenanceandrepairwork
must be performed by a qualified technician or
electrician.
•Do not remove or paint over any DANGER!,
WARNING!,CAUTION!,orinstructionalmateri-
als at tached to the compressor.
•Periodicallycheckallpressurereliefvalvesfor
proper op eration.
•Donotchangethepressuresettingofthepressure
relief valve, re strict the function of the pressure
relief valve, or replace the pressure relief valve
with a plug.
•Donotinstallashutoffvalveinthecompressor
discharge line with out first installing a pres sure
relief valve of proper size and design be tween the
shutoff valve and the compressor.
•Donotmakealterationstothiscompressor.
•Donotoperatethecompressorinexcessofits
135 p.s.i. service rat ing.
•Priortouse,makeageneraloverallinspection
of the unit and correct any unsafe situations. All
fasteners must be kept tight.
•Ifforanyreasonanypartofthemanualbecomes
illegible or the manual is lost, have it re placed
immediately. The instruction manual should be
read periodically to refresh one’s memory.
•Wearsafetyglassesandhearingprotectionduring
operation, service & maintenance proce dures.
DANGER !
Air used for breathing or food processing must meet
OSHA 29 CFR 1910.134 or FDA 21 CFR 178.3570
regula tions. Failure to do so may cause severe injury
or death.
The owner, lessor or operator of any compressor
unit sold by Quincy Compressor is hereby warned that
failure to ob serve the safety precautions and proce-
dures outlined in this manual may result in serious
personal injury, damage to property, and may void
your warranty. Quincy Compressor must authorize all
warranty service. Before contacting your distributor
or the factory, check the maintenance requirements
and the troubleshooting guide for your compressor.
Most warranty issues can be resolved by following
proper maintenance procedures.
Quincy Compressor neither states as fact, nor
in any way implies that the above list of safety pre-
cautions is an all inclusive list, the observance of
which will prevent all damage to property or in jury
to personnel.
Everyefforthasbeentakentoensurethatcom
plete and correct instructions have been in cluded
in this manual. However, possible prod uct up dates
and changes may have occurred since this printing.
Quincy Compressor re serves the right to change
specifications with out incurring any obligation for
equipment previ ously or subse quently sold.
DESCRIPTION
& APPLICATION
Quincy single stage compressors are air-cooled and
splash lubricated. It is the installers responsibility
to meet the appropriate codes and regulations for
this type of installation.
INSTALLATION
Quincy air compressors should be operated in a se-
cure upright position and located in an area that is
clean, dry, well lighted, and adequately ventilated.
The compressor belt guard must not be located closer
than 18 inches to a wall, or 24 inches to an other com-
pressor. Additional safety can be achieved by locating
the pulley drive system, with the guard, next to the
wall. Do not allow hot air from additional equipment
to blow towards the compressor.
It is recommended that the compressor be oper-
ated in temperatures under 104°F and over 32°F. In
cold climates, the compressor should be in stalled in
a heated building.
DANGER !
Under no circumstances should a compressor be
used in an area where toxic, volatile, or corrosive
agents are used or stored near the compressor.
Noise
Federal and local laws govern acceptable noise levels;
should a question about noise levels arise, check with
local officials for specifications.