3 Installation
3.1 General remarks
When installing the filter, keep in mind the following:
Be sure that the piping is internally clean, especially downstream of the filter.
When selecting the filter size, take care that the maximum flow capacity is not exceeded to make sure
that filtration performance and filter lifetime are guaranteed.
Take into account the flow direction:
The filters must be mounted vertically:
If the unit is integrated in a multiple line system, provide isolating valves and (if required) a bypass.
The automatic drain has a special connection allowing easy installation of a hose or a quick coupling
to pipe away the drained liquid. This drained liquid should be fed into a non-pressurized vessel or
drain pipe. In case two filters are installed next to each other, the drain pipe length per filter should be
at least 2 meters before connecting them together. The pipe diameter of the collector should be at least
twice the diameter of the pipes connected to the filter drain.
Open and close isolating valves slowly, as a sudden pressure rise or pressure drop can cause
irreversible damage to the filter element.