Instruction manual
QR-25 Series  Quincy Compressor
52201-107, December 2012  28  3501 Wismann Lane, Quincy IL - 62305-3116
*Not applicable to models without oil pumps.
Pix 1068
Fig. 5-4 
Compressor Directional Ar-
rows
OIL RETURN PORT
FROM THE OIL FILTER
COUNTERSUNK
PIPE PLUG
OIL SUPPLY PORTS
TO THE OIL FILTER
Pix 1154
Fig. 5-6 Relocating
Countersunk Pipe Plug
5120_31.TIF
Fig. 5-5 
Driveshaft Alignment
CAUTION! 
MAKE SURE THE FORKS OF THE BEARING 
CARRIER DRIVESHAFT LINE UP PROPERLY 
WITH THE PIN IN THE END OF THE CRANK-
SHAFT DURING REASSEMBLY!
Step 2) Rotate the oil pump housing 
1
/
2
 turn (180°).  Note: The rota tional 
arrow at the top of the pump housing should now reference 
the direction you wish the compressor to rotate. Make sure 
the forks of the bearing carrier driveshaft line up properly 
with the pin in the end of the crankshaft during reassembly. 
(See Fig. 5-4, Compressor Directional Arrows and Fig. 5-5, 
Driveshaft Alignment.)
Step 3) Re-install the six (6) housing bolts and torque them in a star or 
cross pattern to specifications outlined in the parts book.
Step 4) Remove the countersunk pipe plug
*
 from the oil pump housing and 
relocate it in the opposite (bottom) hole. (See Fig. 5-6, Relocating 
Countersunk Pipe Plug)
Failure to relocate this pipe plug will re sult in complete loss of oil flow 
throughout the compressor. Compressor seizure will result and warranty 
will be void. The countersunk pipe plug must always be relocated in the 
bot tom port position.
Step 5)  Install a new oil filter*. Tighten the filter 
1
/
2
 turn after initial gasket 
con tact.
Step 6)  Re-assemble the control components in reverse order.
Step 7)  Double check the directional arrows.
Step 8)  For aircooled models only, remove the standard compressor sheave 
and replace with a reverse rotation sheave available from your 
local Quincy Compressor distributor.
Step 9)  Start the compressor and adjust the oil pressure.